Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo): time 0.5361/0.5361, allocations: 111.7 MB / 121.5 MB, free: 4.82 MB / 122.7 MB Notification: Performance of NFInstanceAPI.mkTop(): time 0.09597/0.6321, allocations: 33.98 MB / 155.5 MB, free: 3.742 MB / 154.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/package.mo) Running command: setCommandLineOptions("--fmiFlags=s:cvode") Running command: "" <> buildModelFMU(ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip",fmuType="me_cs",version="2.0+3.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip",fmuType="me_cs",version="2.0+3.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.633e-06/1.633e-06, allocations: 0 / 156.7 MB, free: 2.52 MB / 154.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.62e-05/1.783e-05, allocations: 2.312 kB / 156.7 MB, free: 2.516 MB / 154.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip): time 1.103/1.103, allocations: 309.5 MB / 466.2 MB, free: 6.383 MB / 458.7 MB Notification: Performance of NFInst.instExpressions: time 0.3923/1.495, allocations: 219.6 MB / 0.6698 GB, free: 2.492 MB / 0.573 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01243/1.508, allocations: 239.1 kB / 0.67 GB, free: 2.258 MB / 0.573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeB.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeB.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeB.mo:24:3-25:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeB.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:63:3-64:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:65:3-66:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:67:3-68:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:69:3-70:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:80:3-81:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:82:3-83:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/DynamicDrum.mo:84:3-85:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/BoundaryConditions/SinkP.mo:13:3-14:80:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:48:3-49:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:52:3-53:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:90:3-91:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:94:3-95:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:16:3-17:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:18:3-19:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:20:3-21:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:22:3-23:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StodolaTurbine.mo:42:3-43:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:59:3-60:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:61:3-62:79:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:67:3-68:81:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:69:3-70:79:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SourceQ.mo:13:3-14:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/BoundaryConditions/SinkP.mo:19:3-20:80:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:18:3-19:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:20:3-21:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:12:3-13:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:14:3-15:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:33:3-34:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:35:3-36:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:8:3-9:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Sensors/SensorQ.mo:10:3-11:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:20:3-21:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:24:3-25:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeD.mo:26:3-27:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:18:3-19:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:20:3-21:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/Volumes/VolumeA.mo:26:3-27:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:21:3-22:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:23:3-24:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/FlueGases/BoundaryConditions/SourceQ.mo:14:3-15:78:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01205/1.52, allocations: 4.722 MB / 0.6746 GB, free: 13.52 MB / 0.5886 GB Notification: Performance of NFTyping.typeBindings: time 0.0269/1.547, allocations: 14.46 MB / 0.6887 GB, free: 14.96 MB / 0.6042 GB Notification: Performance of NFTyping.typeClassSections: time 0.04291/1.59, allocations: 25.48 MB / 0.7136 GB, free: 5.484 MB / 0.6198 GB Notification: Performance of NFFlatten.flatten: time 0.5205/2.11, allocations: 87.91 MB / 0.7995 GB, free: 28.16 MB / 0.6668 GB Notification: Performance of NFFlatten.resolveConnections: time 0.03571/2.146, allocations: 26.06 MB / 0.8249 GB, free: 42.45 MB / 0.6824 GB Notification: Performance of NFEvalConstants.evaluate: time 0.07334/2.219, allocations: 41.76 MB / 0.8657 GB, free: 28.24 MB / 0.6824 GB Notification: Performance of NFSimplifyModel.simplify: time 0.03914/2.258, allocations: 27.29 MB / 0.8923 GB, free: 20.88 MB / 0.6824 GB Notification: Performance of NFPackage.collectConstants: time 0.01822/2.277, allocations: 5.729 MB / 0.8979 GB, free: 20.84 MB / 0.6824 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:525:9-525:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:708:9-708:27:writable] Warning: 'cv' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: 'dh1satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: 'dh2satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: 'du1satp_der' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: 'du2satp_der' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteam/IF97_packages.mo:964:9-964:35:writable] Warning: 'h' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: 'dh1satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.2.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: 'dh2satp' is used uninitialized and may cause unexpected behaviour. This is deprecated and will become an error in future releases. Notification: Performance of NFFlatten.collectFunctions: time 0.05618/2.333, allocations: 32.17 MB / 0.9294 GB, free: 5.258 MB / 0.698 GB Notification: Performance of NFScalarize.scalarize: time 0.02388/2.357, allocations: 13.96 MB / 0.943 GB, free: 7.375 MB / 0.7137 GB Notification: Performance of NFVerifyModel.verify: time 0.04463/2.401, allocations: 14.41 MB / 0.9571 GB, free: 8.945 MB / 0.7293 GB Notification: Performance of NFConvertDAE.convert: time 0.09055/2.492, allocations: 53.21 MB / 1.009 GB, free: 6.145 MB / 0.7762 GB Notification: Performance of FrontEnd - DAE generated: time 2.22e-05/2.492, allocations: 0 / 1.009 GB, free: 6.145 MB / 0.7762 GB Notification: Performance of FrontEnd: time 1.853e-06/2.492, allocations: 1.156 kB / 1.009 GB, free: 6.145 MB / 0.7762 GB Notification: Performance of Transformations before backend: time 0.001789/2.494, allocations: 0 / 1.009 GB, free: 6.145 MB / 0.7762 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 10787 * Number of variables: 10787 Notification: Performance of Generate backend data structure: time 0.1109/2.605, allocations: 56.44 MB / 1.064 GB, free: 44 kB / 0.823 GB Notification: Performance of prepare preOptimizeDAE: time 4.241e-05/2.605, allocations: 8.625 kB / 1.064 GB, free: 36 kB / 0.823 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.2467/2.851, allocations: 5.239 MB / 1.069 GB, free: 208.8 MB / 0.823 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0376/2.889, allocations: 7.545 MB / 1.077 GB, free: 208.8 MB / 0.823 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.02865/2.918, allocations: 11.5 MB / 1.088 GB, free: 207.5 MB / 0.823 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.01055/2.928, allocations: 19.8 MB / 1.107 GB, free: 188.6 MB / 0.823 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0109/2.939, allocations: 2.888 MB / 1.11 GB, free: 188.5 MB / 0.823 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.08245/3.022, allocations: 34.58 MB / 1.144 GB, free: 184.1 MB / 0.823 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001289/3.023, allocations: 44.25 kB / 1.144 GB, free: 184.1 MB / 0.823 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.009891/3.033, allocations: 1.154 MB / 1.145 GB, free: 184.1 MB / 0.823 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0009372/3.034, allocations: 1.324 MB / 1.146 GB, free: 184.1 MB / 0.823 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.05295/3.087, allocations: 18.39 MB / 1.164 GB, free: 183.2 MB / 0.823 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.2293/3.316, allocations: 122.2 MB / 1.284 GB, free: 86.84 MB / 0.823 GB Notification: Performance of preOpt comSubExp (simulation): time 0.05259/3.368, allocations: 33.81 MB / 1.317 GB, free: 51.39 MB / 0.823 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.03147/3.4, allocations: 10.08 MB / 1.326 GB, free: 41.34 MB / 0.823 GB Notification: Performance of preOpt evalFunc (simulation): time 0.3592/3.759, allocations: 73.22 MB / 1.398 GB, free: 190.5 MB / 0.823 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0523/3.811, allocations: 22.34 MB / 1.42 GB, free: 189.2 MB / 0.823 GB Notification: Performance of pre-optimization done (n=7290): time 5.337e-05/3.811, allocations: 0 / 1.42 GB, free: 189.2 MB / 0.823 GB Notification: Performance of matching and sorting (n=7298): time 0.4686/4.28, allocations: 143.2 MB / 1.56 GB, free: 97.76 MB / 0.823 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002831/4.28, allocations: 475.6 kB / 1.56 GB, free: 97.28 MB / 0.823 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.008655/4.289, allocations: 8.828 MB / 1.569 GB, free: 90.65 MB / 0.823 GB Notification: Performance of collectPreVariables (initialization): time 0.009799/4.299, allocations: 0.6556 MB / 1.569 GB, free: 90.49 MB / 0.823 GB Notification: Performance of collectInitialEqns (initialization): time 0.003708/4.303, allocations: 6.01 MB / 1.575 GB, free: 85.43 MB / 0.823 GB Notification: Performance of collectInitialBindings (initialization): time 0.0236/4.326, allocations: 25.8 MB / 1.6 GB, free: 62.98 MB / 0.823 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0348/4.361, allocations: 8.441 MB / 1.609 GB, free: 57.77 MB / 0.823 GB Notification: Performance of setup shared object (initialization): time 2.704e-05/4.361, allocations: 306 kB / 1.609 GB, free: 57.46 MB / 0.823 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.02802/4.389, allocations: 8.798 MB / 1.618 GB, free: 49.26 MB / 0.823 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.02899/4.418, allocations: 14.41 MB / 1.632 GB, free: 34.84 MB / 0.823 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 0.3638/4.782, allocations: 59.71 MB / 1.69 GB, free: 155.3 MB / 0.823 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001933/4.782, allocations: 24.62 kB / 1.69 GB, free: 155.3 MB / 0.823 GB Notification: Performance of matching and sorting (n=8138) (initialization): time 0.1285/4.91, allocations: 41.01 MB / 1.73 GB, free: 153 MB / 0.823 GB Notification: Performance of prepare postOptimizeDAE: time 0.0001327/4.911, allocations: 100.9 kB / 1.73 GB, free: 152.9 MB / 0.823 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.00047/4.911, allocations: 152.5 kB / 1.73 GB, free: 152.9 MB / 0.823 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.284/6.195, allocations: 0.5715 GB / 2.302 GB, free: 216.6 MB / 0.9168 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.009288/6.204, allocations: 3.607 MB / 2.305 GB, free: 216.6 MB / 0.9168 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.1485/6.353, allocations: 58.95 MB / 2.363 GB, free: 201.4 MB / 0.9168 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.02554/6.378, allocations: 2.302 MB / 2.365 GB, free: 201.4 MB / 0.9168 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.009585/6.388, allocations: 1.379 MB / 2.366 GB, free: 201.4 MB / 0.9168 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.HP_Economizer_3.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.HP_SuperHeater_2.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.HP_SuperHeater_3.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.IP_SuperHeater_3.TwoPhaseFlowPipe.Q[1] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 427 * Number of states: 0 () * Number of discrete variables: 277 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,HP_Drum.Ce2.b,HP_Drum.Ce3.b,HP_Drum.Cs.a,VolumeEvapHP.Ce2.b,VolumeEvapHP.Ce3.b,IP_Drum.Ce2.b,IP_Drum.Ce3.b,IP_Drum.Cs.a,VolumeEvapMP.Ce2.b,VolumeEvapMP.Ce3.b,VolumeLP.Cs1.a,LP_Drum.Ce2.b,LP_Drum.Ce3.b,VolumeEvapBP.Ce2.b,VolumeEvapBP.Ce3.b,VolumeCond1.Ce1.b,VolumeCond1.Ce2.b,VolumeAlimMPHP.Ce2.b,VolumeECO_HP1_2.Ce2.b,VolumeECO_HP1_2.Ce3.b,VolumeECO_HP2_3.Ce2.b,VolumeECO_HP2_3.Ce3.b,VolumePreTHP.Cs1.a,VolumePreTHP.Cs2.a,VolumeIP.Ce2.b,VolumeIP.Ce3.b,SeparateurMP.Ce2.b,HP_Drum.Ce1.a,HP_Drum.Cm.a,HP_Drum.Cd.b,HP_Drum.Cv.b,HP_Drum.Ce2.a,HP_Drum.Ce3.a,HP_Drum.Cs.b,HP_FeedValve.C1.a,HP_FeedValve.C2.b,HP_SteamValve.C1.a,HP_SteamValve.C2.b,HP_DownComer.C1.a,HP_DownComer.C2.b,VolumeEvapHP.Ce1.a,VolumeEvapHP.Ce2.a,VolumeEvapHP.Cs.b,VolumeEvapHP.Ce3.a,HP_Evaporator.ExchangerFlueGasesMetal.C1.a,HP_Evaporator.ExchangerFlueGasesMetal.C2.b,HP_Evaporator.TwoPhaseFlowPipe.C1.a,HP_Evaporator.TwoPhaseFlowPipe.C2.b,HP_Economizer_4.ExchangerFlueGasesMetal.C1.a,HP_Economizer_4.ExchangerFlueGasesMetal.C2.b,HP_Economizer_4.TwoPhaseFlowPipe.C1.a,HP_Economizer_4.TwoPhaseFlowPipe.C2.b,HP_SuperHeater_1.ExchangerFlueGasesMetal.C1.a,HP_SuperHeater_1.ExchangerFlueGasesMetal.C2.b,HP_SuperHeater_1.TwoPhaseFlowPipe.C1.a,HP_SuperHeater_1.TwoPhaseFlowPipe.C2.b,HP_Economizer_3.ExchangerFlueGasesMetal.C1.a,HP_Economizer_3.ExchangerFlueGasesMetal.C2.b,HP_Economizer_3.TwoPhaseFlowPipe.C1.a,HP_Economizer_3.TwoPhaseFlowPipe.C2.b,HP_Economizer_2.ExchangerFlueGasesMetal.C1.a,HP_Economizer_2.ExchangerFlueGasesMetal.C2.b,HP_Economizer_2.TwoPhaseFlowPipe.C1.a,HP_Economizer_2.TwoPhaseFlowPipe.C2.b,HP_Economizer_1.ExchangerFlueGasesMetal.C1.a,HP_Economizer_1.ExchangerFlueGasesMetal.C2.b,HP_Economizer_1.TwoPhaseFlowPipe.C1.a,HP_Economizer_1.TwoPhaseFlowPipe.C2.b,HP_SuperHeater_2.ExchangerFlueGasesMetal.C1.a,HP_SuperHeater_2.ExchangerFlueGasesMetal.C2.b,HP_SuperHeater_2.TwoPhaseFlowPipe.C1.a,HP_SuperHeater_2.TwoPhaseFlowPipe.C2.b,HP_SuperHeater_3.ExchangerFlueGasesMetal.C1.a,HP_SuperHeater_3.ExchangerFlueGasesMetal.C2.b,HP_SuperHeater_3.TwoPhaseFlowPipe.C1.a,HP_SuperHeater_3.TwoPhaseFlowPipe.C2.b,IP_Drum.Ce1.a,IP_Drum.Cm.a,IP_Drum.Cd.b,IP_Drum.Cv.b,IP_Drum.Ce2.a,IP_Drum.Ce3.a,IP_Drum.Cs.b,IP_FeedValve.C1.a,IP_FeedValve.C2.b,IP_SteamValve.C1.a,IP_SteamValve.C2.b,IP_Evaporator.ExchangerFlueGasesMetal.C1.a,IP_Evaporator.ExchangerFlueGasesMetal.C2.b,IP_Evaporator.TwoPhaseFlowPipe.C1.a,IP_Evaporator.TwoPhaseFlowPipe.C2.b,IP_DownComer.C1.a,IP_DownComer.C2.b,VolumeEvapMP.Ce1.a,VolumeEvapMP.Ce2.a,VolumeEvapMP.Cs.b,VolumeEvapMP.Ce3.a,IP_Economizer.ExchangerFlueGasesMetal.C1.a,IP_Economizer.ExchangerFlueGasesMetal.C2.b,IP_Economizer.TwoPhaseFlowPipe.C1.a,IP_Economizer.TwoPhaseFlowPipe.C2.b,IP_SuperHeater_1.ExchangerFlueGasesMetal.C1.a,IP_SuperHeater_1.ExchangerFlueGasesMetal.C2.b,IP_SuperHeater_1.TwoPhaseFlowPipe.C1.a,IP_SuperHeater_1.TwoPhaseFlowPipe.C2.b,VolumeLP.Ce1.a,VolumeLP.Ce2.a,VolumeLP.Cs1.b,VolumeLP.Cs2.b,IP_SuperHeater_2.ExchangerFlueGasesMetal.C1.a,IP_SuperHeater_2.ExchangerFlueGasesMetal.C2.b,IP_SuperHeater_2.TwoPhaseFlowPipe.C1.a,IP_SuperHeater_2.TwoPhaseFlowPipe.C2.b,IP_SuperHeater_3.ExchangerFlueGasesMetal.C1.a,IP_SuperHeater_3.ExchangerFlueGasesMetal.C2.b,IP_SuperHeater_3.TwoPhaseFlowPipe.C1.a,IP_SuperHeater_3.TwoPhaseFlowPipe.C2.b,LP_Drum.Ce1.a,LP_Drum.Cm.a,LP_Drum.Cd.b,LP_Drum.Cv.b,LP_Drum.Ce2.a,LP_Drum.Ce3.a,LP_Drum.Cs.b,LP_SteamValve.C1.a,LP_SteamValve.C2.b,LP_FeedValve.C1.a,LP_FeedValve.C2.b,LP_DownComer.C1.a,LP_DownComer.C2.b,VolumeEvapBP.Ce1.a,VolumeEvapBP.Ce2.a,VolumeEvapBP.Cs.b,VolumeEvapBP.Ce3.a,LP_Evaporator.ExchangerFlueGasesMetal.C1.a,LP_Evaporator.ExchangerFlueGasesMetal.C2.b,LP_Evaporator.TwoPhaseFlowPipe.C1.a,LP_Evaporator.TwoPhaseFlowPipe.C2.b,HPIP_FeedValve.C1.a,HPIP_FeedValve.C2.b,LP_SuperHeater.ExchangerFlueGasesMetal.C1.a,LP_SuperHeater.ExchangerFlueGasesMetal.C2.b,LP_SuperHeater.TwoPhaseFlowPipe.C1.a,LP_SuperHeater.TwoPhaseFlowPipe.C2.b,SinkP_Gas.C.a,LP_Economizer.ExchangerFlueGasesMetal.C1.a,LP_Economizer.ExchangerFlueGasesMetal.C2.b,LP_Economizer.TwoPhaseFlowPipe.C1.a,LP_Economizer.TwoPhaseFlowPipe.C2.b,HP_Turbine.Ce.a,HP_Turbine.Cs.b,IP_Turbine.Ce.a,IP_Turbine.Cs.b,VolumeIP1.Ce1.a,VolumeIP1.Ce2.a,VolumeIP1.Cs.b,VolumeIP1.Ce3.a,LP_Turbine.Ce.a,LP_Turbine.Cs.b,DoubleDebitHP.Ce.a,DoubleDebitHP.Cs.b,DoubleDebitMP.Ce.a,DoubleDebitMP.Cs.b,MoitieDebitHP.Ce.a,MoitieDebitHP.Cs.b,Condenser.Cv.a,Condenser.Cl.b,Condenser.Cee.a,Condenser.Cse.b,SourceCaloporteur.C.b,PuitsCaloporteur.C.a,Dp_Cond_In.C1.a,Dp_Cond_In.C2.b,VolumeCond1.Ce1.a,VolumeCond1.Ce2.a,VolumeCond1.Cs.b,VolumeCond1.Ce3.a,Dp_Cond_Out2.C1.a,Dp_Cond_Out2.C2.b,VolumeAlimMPHP.Ce1.a,VolumeAlimMPHP.Ce2.a,VolumeAlimMPHP.Cs1.b,VolumeAlimMPHP.Cs2.b,IP_Pump.C1.a,IP_Pump.C2.b,HP_Pump.C1.a,HP_Pump.C2.b,MoitieDebitBP.Ce.a,MoitieDebitBP.Cs.b,DoubleDebitBP.Ce.a,DoubleDebitBP.Cs.b,Dp_LP_Turbine.C1.a,Dp_LP_Turbine.C2.b,DP_HP_Pump.C1.a,DP_HP_Pump.C2.b,DP_IP_Pump.C1.a,DP_IP_Pump.C2.b,Dp_Cond_Out.C1.a,Dp_Cond_Out.C2.b,LP_Pump.C1.a,LP_Pump.C2.b,Dp_Cond_Out1.C1.a,Dp_Cond_Out1.C2.b,ExtractionValve.C1.a,ExtractionValve.C2.b,SensorQ_SteamHP.C1.a,SensorQ_SteamHP.C2.b,SensorQ_WaterHP.C1.a,SensorQ_WaterHP.C2.b,SensorQ_WaterMP.C1.a,SensorQ_WaterMP.C2.b,SensorQ_SteamMP.C1.a,SensorQ_SteamMP.C2.b,SensorQ_SteamBP.C1.a,SensorQ_SteamBP.C2.b,SensorQ_WaterBP.C1.a,SensorQ_WaterBP.C2.b,SensorQ_WaterBP_Out.C1.a,SensorQ_WaterBP_Out.C2.b,SensorQ_WaterCondenser.C1.a,SensorQ_WaterCondenser.C2.b,SensorQ_SteamCondenser.C1.a,SensorQ_SteamCondenser.C2.b,HP_PressureLoss_2.C1.a,HP_PressureLoss_2.C2.b,HP_Turbine_Valve.C1.a,HP_Turbine_Valve.C2.b,VolumeECO_HP1_2.Ce1.a,VolumeECO_HP1_2.Ce2.a,VolumeECO_HP1_2.Cs.b,VolumeECO_HP1_2.Ce3.a,VolumeECO_HP2_3.Ce1.a,VolumeECO_HP2_3.Ce2.a,VolumeECO_HP2_3.Cs.b,VolumeECO_HP2_3.Ce3.a,HPIP_FeedValve1.C1.a,HPIP_FeedValve1.C2.b,HPIP_FeedValve2.C1.a,HPIP_FeedValve2.C2.b,VolumePreTHP.Ce.a,VolumePreTHP.Cs1.b,VolumePreTHP.Cs2.b,VolumePreTHP.Cs3.b,VolumeIP.Ce1.a,VolumeIP.Ce2.a,VolumeIP.Cs.b,VolumeIP.Ce3.a,IP_Turbine_Valve.C1.a,IP_Turbine_Valve.C2.b,SeparateurMP.Ce1.a,SeparateurMP.Ce2.a,SeparateurMP.Cs1.b,SeparateurMP.Cs2.b,HP_PressureLoss_1.C1.a,HP_PressureLoss_1.C2.b,HP_IP_PressureLoss.C1.a,HP_IP_PressureLoss.C2.b,SourceFumees.C.b,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,$whenCondition1) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1338): * Single equations (assignments): 1253 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 63 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 8 * Torn equation systems: 12 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 1 system {(2,100.0%)} * Non-linear Jacobian (size): 7 systems {1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(4,1,62.5%)} * Non-linear torn systems (#iteration vars, #inner vars): 11 systems {(1,1), (1,15), (1,1), (1,15), (1,3), (1,5), (314,2974), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.02331/6.411, allocations: 1.962 MB / 2.368 GB, free: 201.1 MB / 0.9168 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.01894/6.43, allocations: 2.874 MB / 2.371 GB, free: 201.1 MB / 0.9168 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.1322/6.562, allocations: 61.66 MB / 2.431 GB, free: 170 MB / 0.9168 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.1057/6.668, allocations: 46.13 MB / 2.476 GB, free: 133.3 MB / 0.9168 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002085/6.668, allocations: 20 kB / 2.476 GB, free: 133.3 MB / 0.9168 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001186/6.669, allocations: 286.6 kB / 2.477 GB, free: 133.2 MB / 0.9168 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.2437/6.913, allocations: 109.8 MB / 2.584 GB, free: 33.88 MB / 0.9168 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0006847/6.914, allocations: 63.94 kB / 2.584 GB, free: 33.82 MB / 0.9168 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.03635/6.95, allocations: 12.23 MB / 2.596 GB, free: 21.98 MB / 0.9168 GB Notification: Performance of postOpt removeConstants (simulation): time 0.2742/7.224, allocations: 7.792 MB / 2.603 GB, free: 219.9 MB / 0.9168 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.08815/7.312, allocations: 42.06 MB / 2.645 GB, free: 216.6 MB / 0.9168 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.01509/7.327, allocations: 1.651 MB / 2.646 GB, free: 216.6 MB / 0.9168 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.1173/7.445, allocations: 202.1 MB / 2.844 GB, free: 48.12 MB / 0.9168 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 0.0001052/7.445, allocations: 14.97 kB / 2.844 GB, free: 48.12 MB / 0.9168 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.1782/7.623, allocations: 71.49 MB / 2.913 GB, free: 37.17 MB / 0.9168 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.01587/7.639, allocations: 1.154 MB / 2.914 GB, free: 36.89 MB / 0.9168 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.02912/7.668, allocations: 2.395 MB / 2.917 GB, free: 35.34 MB / 0.9168 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.01742/7.685, allocations: 4.187 MB / 2.921 GB, free: 33.56 MB / 0.9168 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01259/7.698, allocations: 1.452 MB / 2.922 GB, free: 32.11 MB / 0.9168 GB Notification: Performance of sorting global known variables: time 0.004474/7.702, allocations: 4.562 MB / 2.927 GB, free: 28.13 MB / 0.9168 GB Notification: Performance of sort global known variables: time 6e-08/7.702, allocations: 0 / 2.927 GB, free: 28.13 MB / 0.9168 GB Notification: Performance of remove unused functions: time 0.04819/7.751, allocations: 15.14 MB / 2.942 GB, free: 13.3 MB / 0.9168 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 40 * Number of states: 242 (HP_Drum.P,HP_Drum.hl,HP_Drum.hv,HP_Drum.Tp,HP_Drum.Vv,VolumeEvapHP.h,HP_Evaporator.ExchangerWall.Tp[1],HP_Evaporator.ExchangerWall.Tp[2],HP_Evaporator.ExchangerWall.Tp[3],HP_Evaporator.TwoPhaseFlowPipe.P[2],HP_Evaporator.TwoPhaseFlowPipe.P[3],HP_Evaporator.TwoPhaseFlowPipe.P[4],HP_Evaporator.TwoPhaseFlowPipe.Q[1],HP_Evaporator.TwoPhaseFlowPipe.Q[2],HP_Evaporator.TwoPhaseFlowPipe.Q[3],HP_Evaporator.TwoPhaseFlowPipe.Q[4],HP_Evaporator.TwoPhaseFlowPipe.h[2],HP_Evaporator.TwoPhaseFlowPipe.h[3],HP_Evaporator.TwoPhaseFlowPipe.h[4],HP_Economizer_4.ExchangerWall.Tp[1],HP_Economizer_4.ExchangerWall.Tp[2],HP_Economizer_4.ExchangerWall.Tp[3],HP_Economizer_4.TwoPhaseFlowPipe.P[2],HP_Economizer_4.TwoPhaseFlowPipe.P[3],HP_Economizer_4.TwoPhaseFlowPipe.P[4],HP_Economizer_4.TwoPhaseFlowPipe.Q[2],HP_Economizer_4.TwoPhaseFlowPipe.Q[3],HP_Economizer_4.TwoPhaseFlowPipe.Q[4],HP_Economizer_4.TwoPhaseFlowPipe.h[2],HP_Economizer_4.TwoPhaseFlowPipe.h[3],HP_Economizer_4.TwoPhaseFlowPipe.h[4],HP_SuperHeater_1.ExchangerWall.Tp[1],HP_SuperHeater_1.ExchangerWall.Tp[2],HP_SuperHeater_1.ExchangerWall.Tp[3],HP_SuperHeater_1.TwoPhaseFlowPipe.P[2],HP_SuperHeater_1.TwoPhaseFlowPipe.P[3],HP_SuperHeater_1.TwoPhaseFlowPipe.P[4],HP_SuperHeater_1.TwoPhaseFlowPipe.Q[1],HP_SuperHeater_1.TwoPhaseFlowPipe.Q[2],HP_SuperHeater_1.TwoPhaseFlowPipe.Q[3],HP_SuperHeater_1.TwoPhaseFlowPipe.h[2],HP_SuperHeater_1.TwoPhaseFlowPipe.h[3],HP_SuperHeater_1.TwoPhaseFlowPipe.h[4],HP_Economizer_3.ExchangerWall.Tp[1],HP_Economizer_3.ExchangerWall.Tp[2],HP_Economizer_3.ExchangerWall.Tp[3],HP_Economizer_3.TwoPhaseFlowPipe.P[2],HP_Economizer_3.TwoPhaseFlowPipe.P[3],HP_Economizer_3.TwoPhaseFlowPipe.P[4],HP_Economizer_3.TwoPhaseFlowPipe.Q[1],HP_Economizer_3.TwoPhaseFlowPipe.Q[2],HP_Economizer_3.TwoPhaseFlowPipe.Q[3],HP_Economizer_3.TwoPhaseFlowPipe.Q[4],HP_Economizer_3.TwoPhaseFlowPipe.h[2],HP_Economizer_3.TwoPhaseFlowPipe.h[3],HP_Economizer_3.TwoPhaseFlowPipe.h[4],HP_Economizer_2.ExchangerWall.Tp[1],HP_Economizer_2.ExchangerWall.Tp[2],HP_Economizer_2.ExchangerWall.Tp[3],HP_Economizer_2.TwoPhaseFlowPipe.P[2],HP_Economizer_2.TwoPhaseFlowPipe.P[3],HP_Economizer_2.TwoPhaseFlowPipe.P[4],HP_Economizer_2.TwoPhaseFlowPipe.Q[1],HP_Economizer_2.TwoPhaseFlowPipe.Q[2],HP_Economizer_2.TwoPhaseFlowPipe.Q[3],HP_Economizer_2.TwoPhaseFlowPipe.Q[4],HP_Economizer_2.TwoPhaseFlowPipe.h[2],HP_Economizer_2.TwoPhaseFlowPipe.h[3],HP_Economizer_2.TwoPhaseFlowPipe.h[4],HP_Economizer_1.ExchangerWall.Tp[1],HP_Economizer_1.ExchangerWall.Tp[2],HP_Economizer_1.ExchangerWall.Tp[3],HP_Economizer_1.TwoPhaseFlowPipe.P[2],HP_Economizer_1.TwoPhaseFlowPipe.P[3],HP_Economizer_1.TwoPhaseFlowPipe.P[4],HP_Economizer_1.TwoPhaseFlowPipe.Q[1],HP_Economizer_1.TwoPhaseFlowPipe.Q[2],HP_Economizer_1.TwoPhaseFlowPipe.Q[3],HP_Economizer_1.TwoPhaseFlowPipe.Q[4],HP_Economizer_1.TwoPhaseFlowPipe.h[2],HP_Economizer_1.TwoPhaseFlowPipe.h[3],HP_Economizer_1.TwoPhaseFlowPipe.h[4],HP_SuperHeater_2.ExchangerWall.Tp[1],HP_SuperHeater_2.ExchangerWall.Tp[2],HP_SuperHeater_2.ExchangerWall.Tp[3],HP_SuperHeater_2.TwoPhaseFlowPipe.P[2],HP_SuperHeater_2.TwoPhaseFlowPipe.P[3],HP_SuperHeater_2.TwoPhaseFlowPipe.P[4],HP_SuperHeater_2.TwoPhaseFlowPipe.Q[1],HP_SuperHeater_2.TwoPhaseFlowPipe.Q[2],HP_SuperHeater_2.TwoPhaseFlowPipe.Q[3],HP_SuperHeater_2.TwoPhaseFlowPipe.h[2],HP_SuperHeater_2.TwoPhaseFlowPipe.h[3],HP_SuperHeater_2.TwoPhaseFlowPipe.h[4],HP_SuperHeater_3.ExchangerWall.Tp[1],HP_SuperHeater_3.ExchangerWall.Tp[2],HP_SuperHeater_3.ExchangerWall.Tp[3],HP_SuperHeater_3.TwoPhaseFlowPipe.P[2],HP_SuperHeater_3.TwoPhaseFlowPipe.P[3],HP_SuperHeater_3.TwoPhaseFlowPipe.P[4],HP_SuperHeater_3.TwoPhaseFlowPipe.Q[1],HP_SuperHeater_3.TwoPhaseFlowPipe.Q[2],HP_SuperHeater_3.TwoPhaseFlowPipe.Q[3],HP_SuperHeater_3.TwoPhaseFlowPipe.Q[4],HP_SuperHeater_3.TwoPhaseFlowPipe.h[2],HP_SuperHeater_3.TwoPhaseFlowPipe.h[3],HP_SuperHeater_3.TwoPhaseFlowPipe.h[4],IP_Drum.P,IP_Drum.hl,IP_Drum.hv,IP_Drum.Tp,IP_Drum.Vv,IP_Evaporator.ExchangerWall.Tp[1],IP_Evaporator.ExchangerWall.Tp[2],IP_Evaporator.ExchangerWall.Tp[3],IP_Evaporator.TwoPhaseFlowPipe.P[2],IP_Evaporator.TwoPhaseFlowPipe.P[3],IP_Evaporator.TwoPhaseFlowPipe.P[4],IP_Evaporator.TwoPhaseFlowPipe.Q[1],IP_Evaporator.TwoPhaseFlowPipe.Q[2],IP_Evaporator.TwoPhaseFlowPipe.Q[3],IP_Evaporator.TwoPhaseFlowPipe.Q[4],IP_Evaporator.TwoPhaseFlowPipe.h[2],IP_Evaporator.TwoPhaseFlowPipe.h[3],IP_Evaporator.TwoPhaseFlowPipe.h[4],VolumeEvapMP.h,IP_Economizer.ExchangerWall.Tp[1],IP_Economizer.ExchangerWall.Tp[2],IP_Economizer.ExchangerWall.Tp[3],IP_Economizer.TwoPhaseFlowPipe.P[2],IP_Economizer.TwoPhaseFlowPipe.P[3],IP_Economizer.TwoPhaseFlowPipe.P[4],IP_Economizer.TwoPhaseFlowPipe.Q[1],IP_Economizer.TwoPhaseFlowPipe.Q[2],IP_Economizer.TwoPhaseFlowPipe.Q[3],IP_Economizer.TwoPhaseFlowPipe.Q[4],IP_Economizer.TwoPhaseFlowPipe.h[2],IP_Economizer.TwoPhaseFlowPipe.h[3],IP_Economizer.TwoPhaseFlowPipe.h[4],IP_SuperHeater_1.ExchangerWall.Tp[1],IP_SuperHeater_1.ExchangerWall.Tp[2],IP_SuperHeater_1.ExchangerWall.Tp[3],IP_SuperHeater_1.TwoPhaseFlowPipe.P[2],IP_SuperHeater_1.TwoPhaseFlowPipe.P[3],IP_SuperHeater_1.TwoPhaseFlowPipe.P[4],IP_SuperHeater_1.TwoPhaseFlowPipe.h[2],IP_SuperHeater_1.TwoPhaseFlowPipe.h[3],IP_SuperHeater_1.TwoPhaseFlowPipe.h[4],VolumeLP.h,IP_SuperHeater_2.ExchangerWall.Tp[1],IP_SuperHeater_2.ExchangerWall.Tp[2],IP_SuperHeater_2.ExchangerWall.Tp[3],IP_SuperHeater_2.TwoPhaseFlowPipe.P[2],IP_SuperHeater_2.TwoPhaseFlowPipe.P[3],IP_SuperHeater_2.TwoPhaseFlowPipe.P[4],IP_SuperHeater_2.TwoPhaseFlowPipe.Q[1],IP_SuperHeater_2.TwoPhaseFlowPipe.Q[2],IP_SuperHeater_2.TwoPhaseFlowPipe.Q[3],IP_SuperHeater_2.TwoPhaseFlowPipe.h[2],IP_SuperHeater_2.TwoPhaseFlowPipe.h[3],IP_SuperHeater_2.TwoPhaseFlowPipe.h[4],IP_SuperHeater_3.ExchangerWall.Tp[1],IP_SuperHeater_3.ExchangerWall.Tp[2],IP_SuperHeater_3.ExchangerWall.Tp[3],IP_SuperHeater_3.TwoPhaseFlowPipe.P[2],IP_SuperHeater_3.TwoPhaseFlowPipe.P[3],IP_SuperHeater_3.TwoPhaseFlowPipe.P[4],IP_SuperHeater_3.TwoPhaseFlowPipe.Q[1],IP_SuperHeater_3.TwoPhaseFlowPipe.Q[2],IP_SuperHeater_3.TwoPhaseFlowPipe.Q[3],IP_SuperHeater_3.TwoPhaseFlowPipe.Q[4],IP_SuperHeater_3.TwoPhaseFlowPipe.h[2],IP_SuperHeater_3.TwoPhaseFlowPipe.h[3],IP_SuperHeater_3.TwoPhaseFlowPipe.h[4],LP_Drum.P,LP_Drum.hl,LP_Drum.hv,LP_Drum.Tp,LP_Drum.Vv,VolumeEvapBP.h,LP_Evaporator.ExchangerWall.Tp[1],LP_Evaporator.ExchangerWall.Tp[2],LP_Evaporator.ExchangerWall.Tp[3],LP_Evaporator.TwoPhaseFlowPipe.P[2],LP_Evaporator.TwoPhaseFlowPipe.P[3],LP_Evaporator.TwoPhaseFlowPipe.P[4],LP_Evaporator.TwoPhaseFlowPipe.Q[1],LP_Evaporator.TwoPhaseFlowPipe.Q[2],LP_Evaporator.TwoPhaseFlowPipe.Q[3],LP_Evaporator.TwoPhaseFlowPipe.Q[4],LP_Evaporator.TwoPhaseFlowPipe.h[2],LP_Evaporator.TwoPhaseFlowPipe.h[3],LP_Evaporator.TwoPhaseFlowPipe.h[4],LP_SuperHeater.ExchangerWall.Tp[1],LP_SuperHeater.ExchangerWall.Tp[2],LP_SuperHeater.ExchangerWall.Tp[3],LP_SuperHeater.TwoPhaseFlowPipe.P[2],LP_SuperHeater.TwoPhaseFlowPipe.P[3],LP_SuperHeater.TwoPhaseFlowPipe.P[4],LP_SuperHeater.TwoPhaseFlowPipe.h[2],LP_SuperHeater.TwoPhaseFlowPipe.h[3],LP_SuperHeater.TwoPhaseFlowPipe.h[4],LP_Economizer.ExchangerWall.Tp[1],LP_Economizer.ExchangerWall.Tp[2],LP_Economizer.ExchangerWall.Tp[3],LP_Economizer.TwoPhaseFlowPipe.P[2],LP_Economizer.TwoPhaseFlowPipe.P[3],LP_Economizer.TwoPhaseFlowPipe.P[4],LP_Economizer.TwoPhaseFlowPipe.Q[1],LP_Economizer.TwoPhaseFlowPipe.Q[2],LP_Economizer.TwoPhaseFlowPipe.Q[3],LP_Economizer.TwoPhaseFlowPipe.Q[4],LP_Economizer.TwoPhaseFlowPipe.h[2],LP_Economizer.TwoPhaseFlowPipe.h[3],LP_Economizer.TwoPhaseFlowPipe.h[4],VolumeIP1.h,Condenser.P,Condenser.hl,Condenser.hv,Condenser.Vv,VolumeCond1.h,VolumeAlimMPHP.h,regulation_Niveau_HP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_3.x,VolumeECO_HP1_2.P,VolumeECO_HP1_2.h,VolumeECO_HP2_3.P,VolumeECO_HP2_3.h,VolumePreTHP.P,VolumePreTHP.h,VolumeIP.P,VolumeIP.h,SeparateurMP.h) * Number of discrete variables: 9 ($whenCondition1,regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (4700): * Single equations (assignments): 4253 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 265 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 170 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 5 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 65 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 105 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,15), (1,6), (1,15), (1,6), (1,5), (1,2), (1,2), (1,2), (1,2), (1,3), (1,6), (13,70), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,6), (1,6), (1,6), (1,15), (1,15), (1,6), (1,6), (1,6), (1,5), (1,3), (6,14), (1,3), (6,14), (1,3), (1,3), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (1,4), (1,4), (1,4), (1,5), (1,3), (8,15), (4,20), (1,3), (4,22)} Notification: Performance of Backend phase and start with SimCode phase: time 0.4814/8.232, allocations: 77.24 MB / 3.017 GB, free: 194.7 MB / 0.9168 GB Notification: Performance of simCode: created initialization part: time 0.1102/8.342, allocations: 101.5 MB / 3.116 GB, free: 128.1 MB / 0.9168 GB Notification: Performance of simCode: created event and clocks part: time 0.0002202/8.343, allocations: 181.3 kB / 3.116 GB, free: 128 MB / 0.9168 GB Notification: Performance of simCode: created simulation system equations: time 0.06761/8.41, allocations: 43.88 MB / 3.159 GB, free: 107.8 MB / 0.9168 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.06829/8.478, allocations: 21.08 MB / 3.18 GB, free: 94.35 MB / 0.9168 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 1.103/9.581, allocations: 234.2 MB / 3.408 GB, free: 168.4 MB / 0.9168 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.01781/9.599, allocations: 10.96 MB / 3.419 GB, free: 160.6 MB / 0.9168 GB Notification: Performance of simCode: alias equations: time 0.02599/9.625, allocations: 4.669 MB / 3.424 GB, free: 157.9 MB / 0.9168 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.05746/9.682, allocations: 30.39 MB / 3.453 GB, free: 142 MB / 0.9168 GB Notification: Performance of SimCode: time 2.405e-06/9.682, allocations: 0 / 3.453 GB, free: 142 MB / 0.9168 GB Notification: Performance of NFInstanceAPI.mkTop(ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip): time 5.521/15.2, allocations: 2.296 GB / 5.749 GB, free: 187.1 MB / 0.9953 GB Notification: Performance of FMU documentation: time 0.003062/15.21, allocations: 2.163 MB / 5.751 GB, free: 185.7 MB / 0.9953 GB Notification: FMU-only work: backend 0.4617, simCode 0.6371, templates 0 Notification: Performance of buildModelFMU: Generate the FMI files: time 0.05787/15.26, allocations: 1.475 MB / 5.752 GB, free: 184.1 MB / 0.9953 GB Notification: Building FMU for platform 'static' (1/1). Notification: Finished FMU for platform 'static' (1/1). Notification: Performance of buildModelFMU: Generate platform static: time 47.85/63.11, allocations: 18.31 kB / 5.753 GB, free: 184.1 MB / 0.9953 GB " [Timeout remaining time 597] (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip.pipe >> ../files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip.sim & (cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip_fmu --startTime=0 --stopTime=10000 --stepSize=4 --mode=me --timeout=240 --tolerance=1e-06 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip.pipe 2>&1) [Timeout 252.0] OMSimulator failed or timed out simulating it; the others still get to run it (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-cvode.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-cvode.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-cvode.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-cvode.sim & (cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=10000 --stepSize=4 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip_OMSimulator-cs-cvode.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-cvode.pipe 2>&1) [Timeout 252.0] OMSimulator-cs-cvode timed out simulating the FMU (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-euler.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-euler.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-euler.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-euler.sim & (cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=10000 --stepSize=4 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip_OMSimulator-cs-euler.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_OMSimulator-cs-euler.pipe 2>&1) [Timeout 252.0] OMSimulator-cs-euler timed out simulating the FMU (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy.sim & (cd run_fmpy && python3 -m fmpy simulate --output-file ../ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy_res.csv --start-time 0 --stop-time 10000 --timeout 240 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 4 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy.pipe 2>&1) [Timeout 252.0] fmpy timed out simulating the FMU (rm -f ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy-fmi3-cs-cvode.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy-fmi3-cs-cvode.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy-fmi3-cs-cvode.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy-fmi3-cs-cvode.sim & (cd run_fmpy-fmi3-cs-cvode && python3 -m fmpy simulate --output-file ../ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy-fmi3-cs-cvode_res.csv --start-time 0 --stop-time 10000 --timeout 240 --relative-tolerance 1e-06 --interface-type CoSimulation --output-interval 4 ../ThermoSysPro_ThermoSysPro_Examples_Book_PowerPlants_CombinedCyclePowerPlant_GasTurbineTrip_fmpy-fmi3-cs-cvode.fmu) > ThermoSysPro_ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip_fmpy-fmi3-cs-cvode.pipe 2>&1) [Timeout 252.0] fmpy-fmi3-cs-cvode timed out simulating the FMU [Calling sys.exit(0), Time elapsed: 295.656668885611]