(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=7200 --stepSize=7.2 --mode=cs --timeout=240 --tolerance=1e-06 ../TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 7.2 LOG_STDOUT | info | iteration to converge on Fview: 8 warning: [fmi2Warning] Room_with_wood_burner/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:21: the Rayleigh number > 10^12 is out of the range of the correlation warning: [fmi2Warning] Room_with_wood_burner/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/Functions/FreeConvection/ceiling_ASHRAE.mo:58: the Rayleigh number <10^5 is out of the range of the correlation warning: [fmi2Warning] Room_with_wood_burner/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:52: the Rayleigh number >1.5*10^9 is out of the range of the correlation warning: [fmi2Warning] Room_with_wood_burner/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/Functions/FreeConvection/ceiling_ASHRAE.mo:53: the Rayleigh number >1.5*10^9 is out of the range of the correlation warning: [fmi2Warning] Room_with_wood_burner/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:58: the Rayleigh number >10^9 is out of the range of the correlation warning: [fmi2Warning] Room_with_wood_burner/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20: the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated warning: [fmi2Warning] Room_with_wood_burner/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/BasesClasses/FreeConvection_dT_decoupled.mo:30: The following assertion has been violated at time 0.000000 ((wood_burner.convection_emitter.T_mean >= 273.15 and wood_burner.convection_emitter.T_mean <= 373.15), wood_burner.convection_emitter.T_mean=563.6280113818682) --> "Variable violating min/max constraint: 273.15 <= wood_burner.convection_emitter.T_mean <= 373.15, has value: 563.628" info: Result file: TAeZoSysPro_TAeZoSysPro_HeatTransfer_Examples_Room_with_wood_burner_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: 7 warnings info: 0 errors