(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../PowerGrids_dev_PowerGrids.Examples.Tutorial.GridOperation.Static.StaticGridDifferentNominals_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_PowerGrids_dev_PowerGrids_Examples_Tutorial_GridOperation_Static_StaticGridDifferentNominals_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=2 --stepSize=0.004 --mode=cs --timeout=240 --tolerance=1e-06 ../PowerGrids_dev_PowerGrids_Examples_Tutorial_GridOperation_Static_StaticGridDifferentNominals_OMSimulator-cs-cvode.fmu) LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. info: *** FMU Simulation Info *** - model : PowerGrids.Examples.Tutorial.GridOperation.Static.StaticGridDifferentNominals (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 2.000000 - tolerance : 1e-06 - stepSize : 0.004 warning: [fmi2Warning] StaticGridDifferentNominals/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35: The following assertion has been violated during initialization at time 0.000000 ((GEN_2.componentPF.IPuCheck < GEN_2.componentPF.IPuMax), GEN_2.componentPF.IPuCheck=5.318019003015348, GEN_2.componentPF.IPuMax=2.5) --> "Current too high (IPu=5.31802 > 2.5), check if the numerical solution is valid" warning: [fmi2Warning] StaticGridDifferentNominals/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35: The following assertion has been violated during initialization at time 0.000000 ((GRID_2.componentPF.IPuCheck < GRID_2.componentPF.IPuMax), GRID_2.componentPF.IPuCheck=4.593078809163227, GRID_2.componentPF.IPuMax=2.5) --> "Current too high (IPu=4.59308 > 2.5), check if the numerical solution is valid" warning: [fmi2Warning] StaticGridDifferentNominals/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35: The following assertion has been violated during initialization at time 0.000000 ((GEN_2.IPuCheck < GEN_2.IPuMax), GEN_2.IPuCheck=5.318019003015345, GEN_2.IPuMax=2.5) --> "Current too high (IPu=5.31802 > 2.5), check if the numerical solution is valid" warning: [fmi2Warning] StaticGridDifferentNominals/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35: The following assertion has been violated during initialization at time 0.000000 ((GRID_2.IPuCheck < GRID_2.IPuMax), GRID_2.IPuCheck=4.593078809163225, GRID_2.IPuMax=2.5) --> "Current too high (IPu=4.59308 > 2.5), check if the numerical solution is valid" warning: [fmi2Warning] StaticGridDifferentNominals/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:33: The following assertion has been violated during initialization at time 0.000000 ((GEN_3.componentPF.VPuCheck < GEN_3.componentPF.VPuMax), GEN_3.componentPF.VPuCheck=2.1, GEN_3.componentPF.VPuMax=1.3) --> "Voltage too high (VPu=2.1 > 1.3), check if the numerical solution is valid" warning: [fmi2Warning] StaticGridDifferentNominals/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:33: The following assertion has been violated during initialization at time 0.000000 ((GEN_3.VPuCheck < GEN_3.VPuMax), GEN_3.VPuCheck=2.100000000000001, GEN_3.VPuMax=1.3) --> "Voltage too high (VPu=2.1 > 1.3), check if the numerical solution is valid" info: Result file: ../PowerGrids_dev_PowerGrids.Examples.Tutorial.GridOperation.Static.StaticGridDifferentNominals_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: 6 warnings info: 0 errors