(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Physiolibrary_Physiolibrary_Fluid_Examples_BloodGasesTransport_BloodyMary_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1800 --stepSize=0.72 --mode=cs --timeout=240 --tolerance=1e-06 ../Physiolibrary_Physiolibrary_Fluid_Examples_BloodGasesTransport_BloodyMary_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Physiolibrary.Fluid.Examples.BloodGasesTransport.BloodyMary (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1800.000000 - tolerance : 1e-06 - stepSize : 0.72 warning: [fmi2Warning] BloodyMary/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary 3.0.0/Fluid.mo:786: The following assertion has been violated at time 0.000000 ((pulmonaryVeins.massOffset >= 0.0), pulmonaryVeins.massOffset=-9.968476835653384e-09) --> "Variable violating min constraint: 0.0 <= pulmonaryVeins.massOffset, has value: -9.96848e-09" warning: [fmi2Warning] BloodyMary/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary 3.0.0/Fluid.mo:786: The following assertion has been violated at time 0.000000 ((systemicArteries.massOffset >= 0.0), systemicArteries.massOffset=-2.11830132879065e-08) --> "Variable violating min constraint: 0.0 <= systemicArteries.massOffset, has value: -2.1183e-08" warning: [fmi2Warning] BloodyMary/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary 3.0.0/Fluid.mo:786: The following assertion has been violated at time 0.000000 ((respiratoryUnit[1].pulmCapysVentilated.massOffset >= 0.0), respiratoryUnit[1].pulmCapysVentilated.massOffset=-3.738178822043636e-09) --> "Variable violating min constraint: 0.0 <= respiratoryUnit[1].pulmCapysVentilated.massOffset, has value: -3.73818e-09" info: Result file: Physiolibrary_Physiolibrary_Fluid_Examples_BloodGasesTransport_BloodyMary_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter BloodyMary.arterial.pCO2_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Variable BloodyMary.arterial.pH_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.arterial.pO2_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.pulmonaryArteries.stateName will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.pulmonaryVeins.stateName will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.respiratoryUnit[1].alveolar.pCO2_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Variable BloodyMary.respiratoryUnit[1].alveolar.pH_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.respiratoryUnit[1].alveolar.pO2_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.respiratoryUnit[1].alveoli.stateName will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.respiratoryUnit[1].pulmCapysVentilated.stateName will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.systemicArteries.stateName will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.systemicVeins.stateName will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.tissueUnit[1].CO2_left.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.tissueUnit[1].systemicCapillaries.stateName will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.tissueUnit[1].tissue.pCO2_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Variable BloodyMary.tissueUnit[1].tissue.pH_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.tissueUnit[1].tissue.pO2_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.venous.pCO2_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Variable BloodyMary.venous.pH_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter BloodyMary.venous.pO2_measure.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: 3 warnings info: 0 errors