(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=10 --stepSize=0.004 --mode=cs --timeout=240 --tolerance=1e-08 ../OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : OpenHydraulics.DevelopmentTests.DirectionalValveTest (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 10.000000 - tolerance : 1e-08 - stepSize : 0.004 info: Result file: OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable DirectionalValveTest.oil.oilName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | The following assertion has been violated at time 0.000002