(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_WaterWaterTSet_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --mode=cs --timeout=240 --tolerance=1e-06 ../IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_WaterWaterTSet_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : IDEAS.Fluid.HeatPumps.Examples.HeatPump_WaterWaterTSet (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1000.000000 - tolerance : 1e-06 - stepSize : 0.4 warning: [fmi2Warning] HeatPump_WaterWaterTSet/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: The following assertion has been violated during initialization at time 0.000000 ((pump1.nominalValuesDefineDefaultPressureCurve), pump1.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in HeatPump_WaterWaterTSet.pump1: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." warning: [fmi2Warning] HeatPump_WaterWaterTSet/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: The following assertion has been violated during initialization at time 0.000000 ((pump.nominalValuesDefineDefaultPressureCurve), pump.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in HeatPump_WaterWaterTSet.pump: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: Result file: IDEAS_dev_IDEAS_Fluid_HeatPumps_Examples_HeatPump_WaterWaterTSet_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter HeatPump_WaterWaterTSet.heatPump.copTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_WaterWaterTSet.heatPump.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_WaterWaterTSet.heatPump.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_WaterWaterTSet.heatPump.powerTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_WaterWaterTSet.heatPump.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatPump_WaterWaterTSet.heatPump.powerTable.tableName will not be stored in the result file, because the signal type is not supported info: 2 warnings info: 0 errors