(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Chemical_master_Chemical_Obsolete_Examples_WaterSublimation_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=49.7 --stepSize=0.01988 --mode=cs --timeout=240 --tolerance=1e-06 ../Chemical_master_Chemical_Obsolete_Examples_WaterSublimation_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Chemical.Obsolete.Examples.WaterSublimation (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 49.700000 - tolerance : 1e-06 - stepSize : 0.01988 warning: [fmi2Warning] WaterSublimation/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.1-master/Obsolete.mo:14347: The following assertion has been violated at time 0.000000 ((gas.mass >= 0.0 and gas.mass <= 0.0), gas.mass=0.032018015) --> "Variable violating min/max constraint: 0.0 <= gas.mass <= 0.0, has value: 0.032018" warning: [fmi2Warning] WaterSublimation/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.1-master/Obsolete.mo:14160: The following assertion has been violated at time 0.000000 ((otherSubstances.solution.n >= 0.0 and otherSubstances.solution.n <= 0.0), otherSubstances.solution.n=1.001) --> "Variable violating min/max constraint: 0.0 <= otherSubstances.solution.n <= 0.0, has value: 1.001" warning: [fmi2Warning] WaterSublimation/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.1-master/Obsolete.mo:14347: The following assertion has been violated at time 0.000000 ((solid.mass >= 0.0 and solid.mass <= 0.0), solid.mass=0.9999766199999999) --> "Variable violating min/max constraint: 0.0 <= solid.mass <= 0.0, has value: 0.999977" warning: [fmi2Warning] WaterSublimation/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.1-master/Obsolete.mo:361: The following assertion has been violated at time 0.000000 ((H2O_solid.amountOfBaseMolecules >= 0.0 and H2O_solid.amountOfBaseMolecules <= 0.0), H2O_solid.amountOfBaseMolecules=55.508) --> "Variable violating min/max constraint: 0.0 <= H2O_solid.amountOfBaseMolecules <= 0.0, has value: 55.508" info: Result file: Chemical_master_Chemical_Obsolete_Examples_WaterSublimation_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter WaterSublimation.H2O_gaseuous.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter WaterSublimation.H2O_solid.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter WaterSublimation.otherSubstances.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: 4 warnings info: 0 errors