(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariable_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneOneOutputVariable_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=432000 --stepSize=172.8 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneOneOutputVariable_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariable (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 432000.000000 - tolerance : 1e-06 - stepSize : 172.8 LOG_STDOUT | warning | The nominal value of zon.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.14 00:09 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneOneOutputVariable.equEle.y has in Modelica the unit 1. warning: [fmi2Warning] OneZoneOneOutputVariable/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 0.000000 ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.59347278997302e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariable_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter OneZoneOneOutputVariable.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariable.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariable.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariable.equEle.key will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariable.equEle.name will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariable.zon.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariable.zon.zoneName will not be stored in the result file, because the signal type is not supported Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.34sec EnergyPlus Completed Successfully. info: 1 warnings info: 0 errors