(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_Infiltration_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_Infiltration_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.Infiltration (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 warning: [fmi2Warning] Infiltration/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/ThermalZones/EnergyPlus_24_2_0/Examples/SingleFamilyHouse_TwoSpeed_ZoneAirBalance/SingleFamilyHouse_TwoSpeed_ZoneAirBalance_aboveSoilHighInfiltration.idf) not in the resources directory. The FMU might not work as expected if you send it to a different system EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 06:15 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 06:15 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD warning: [fmi2Warning] Infiltration/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 0.000000 ((defInf.duc.m_flow >= 0.0 and defInf.duc.m_flow <= 1e5), defInf.duc.m_flow=-6.593472789973019e-15) --> "Variable violating min/max constraint: 0.0 <= defInf.duc.m_flow <= 1e5, has value: -6.59347e-15" warning: [fmi2Warning] Infiltration/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 0.000000 ((higInf.duc.m_flow >= 0.0 and higInf.duc.m_flow <= 1e5), higInf.duc.m_flow=-6.593472789973019e-15) --> "Variable violating min/max constraint: 0.0 <= higInf.duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_Infiltration_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter Infiltration.defInf.attFlo.surfaceName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.defInf.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.defInf.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.defInf.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.defInf.livFlo.surfaceName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.defInf.zon.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.higInf.attFlo.surfaceName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.higInf.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.higInf.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.higInf.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.higInf.livFlo.surfaceName will not be stored in the result file, because the signal type is not supported info: Parameter Infiltration.higInf.zon.zoneName will not be stored in the result file, because the signal type is not supported Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 5.65sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.47sec EnergyPlus Completed Successfully. info: 3 warnings info: 0 errors