(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Templates_Components_Validation_Coils_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=200 --stepSize=0.08 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Templates_Components_Validation_Coils_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Buildings.Templates.Components.Validation.Coils (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 200.000000 - tolerance : 1e-06 - stepSize : 0.08 warning: [fmi2Warning] Coils/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185: The following assertion has been violated during initialization at time 0.000000 ((coiMul.hex.watVapEva.nomVal.gamma <= coiMul.hex.watVapEva.gammaMax), coiMul.hex.watVapEva.nomVal.gamma=1.5, coiMul.hex.watVapEva.gammaMax=0.2450160348537442) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. Instead of gamma = 1.5, a value of 0.245016, which corresponds to a mass transfer effectiveness of 0.8, will be used. Coil nominal performance data are: nomVal.m_flow_nominal = 4.5312 dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00546923 - 0.0059222 = -0.000452973 QLat_flow_nominal = -16760.9 warning: [fmi2Warning] Coils/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185: The following assertion has been violated during initialization at time 0.000000 ((coiEva.hex.watVapEva.nomVal.gamma <= coiEva.hex.watVapEva.gammaMax), coiEva.hex.watVapEva.nomVal.gamma=1.5, coiEva.hex.watVapEva.gammaMax=0.3102064990529056) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. Instead of gamma = 1.5, a value of 0.310206, which corresponds to a mass transfer effectiveness of 0.8, will be used. Coil nominal performance data are: nomVal.m_flow_nominal = 1.1328 dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00527094 - 0.00592132 = -0.000650382 QLat_flow_nominal = -4752.01 info: Result file: Buildings_13_Buildings_Templates_Components_Validation_Coils_OMSimulator-cs-cvode_res.mat (bufferSize=10) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121:7-134:38:writable] | | | | The following assertion has been violated at time 50.000000 | | | | ((not (coiMul.hex.dxCoi.wetCoi.wetBul.TWetBul > coiMul.hex.dxCoi.wetCoi.coiCap.sta[1].perCur.TEvaInMax or coiMul.hex.dxCoi.wetCoi.wetBul.TWetBul < coiMul.hex.dxCoi.wetCoi.coiCap.sta[1].perCur.TEvaInMin)), coiMul.hex.dxCoi.wetCoi.wetBul.TWetBul=286.4567844024629, coiMul.hex.dxCoi.wetCoi.coiCap.sta[1].perCur.TEvaInMax=294.82, coiMul.hex.dxCoi.wetCoi.coiCap.sta[1].perCur.TEvaInMin=290.37) --> "*** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 50. | | | | stage = 1 | | | | TEvaInMin = 290.37 Kelvin (17.22 degC) | | | | TEvaIn = 286.457 Kelvin (13.3068 degC) | | | | TEvaInMax = 294.82 Kelvin (21.67 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121:7-134:38:writable] | | | | The following assertion has been violated at time 100.000000 | | | | ((not (coiMul.hex.dxCoi.wetCoi.wetBul.TWetBul > coiMul.hex.dxCoi.wetCoi.coiCap.sta[2].perCur.TEvaInMax or coiMul.hex.dxCoi.wetCoi.wetBul.TWetBul < coiMul.hex.dxCoi.wetCoi.coiCap.sta[2].perCur.TEvaInMin)), coiMul.hex.dxCoi.wetCoi.wetBul.TWetBul=286.4567844024629, coiMul.hex.dxCoi.wetCoi.coiCap.sta[2].perCur.TEvaInMax=294.82, coiMul.hex.dxCoi.wetCoi.coiCap.sta[2].perCur.TEvaInMin=290.37) --> "*** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 100. | | | | stage = 2 | | | | TEvaInMin = 290.37 Kelvin (17.22 degC) | | | | TEvaIn = 286.457 Kelvin (13.3068 degC) | | | | TEvaInMax = 294.82 Kelvin (21.67 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage." info: 2 warnings info: 0 errors