(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_CHPs_Validation_ThermalFollowing_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=10000 --stepSize=4 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_CHPs_Validation_ThermalFollowing_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Buildings.Fluid.CHPs.Validation.ThermalFollowing (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 10000.000000 - tolerance : 1e-06 - stepSize : 4 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmphssqhc5v/ThermalFollowing-u7cblsop/temp/0001_ThermalFollowing/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/Fluid/CHPs/Validation/MicroCogeneration.mos" warning: [fmi2Warning] ThermalFollowing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated during initialization at time 0.000000 ((theFolNeg.opeMod.assWatMas.nand.y), theFolNeg.opeMod.assWatMas.nand.y=false) --> "Water flow rate is lower than the minimum!" info: Result file: Buildings_13_Buildings_Fluid_CHPs_Validation_ThermalFollowing_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter ThermalFollowing.avaSig.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.avaSig.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.avaSig.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFol.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFol.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFol.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFolNeg.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFolNeg.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFolNeg.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.valDat.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.valDat.fileName will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.valDat.tableName will not be stored in the result file, because the signal type is not supported info: 1 warnings info: 0 errors