(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Loads_BaseClasses_Examples_CouplingSpawnZ1_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=604800 --stepSize=241.92 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Loads_BaseClasses_Examples_CouplingSpawnZ1_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 604800.000000 - tolerance : 1e-06 - stepSize : 241.92 warning: [fmi2Warning] CouplingSpawnZ1/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system warning: [fmi2Warning] CouplingSpawnZ1/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system warning: [fmi2Warning] CouplingSpawnZ1/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.10 07:38 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Warming up {12} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD info: Result file: Buildings_13_Buildings_DHC_Loads_BaseClasses_Examples_CouplingSpawnZ1_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter CouplingSpawnZ1.bui.epwName will not be stored in the result file, because the signal type is not supported info: Parameter CouplingSpawnZ1.bui.idfName will not be stored in the result file, because the signal type is not supported info: Parameter CouplingSpawnZ1.bui.weaName will not be stored in the result file, because the signal type is not supported info: Parameter CouplingSpawnZ1.bui.zon.zoneName will not be stored in the result file, because the signal type is not supported Updating Shadowing Calculations, Start Date=01/08/2006 Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.97sec EnergyPlus Completed Successfully. info: 3 warnings info: 0 errors