(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Examples_Combined_ETSHeatRecoveryHeatPump_BuildingTimeSeries_WithDHW_OMSimulator-cs-cvode_fmu --startTime=7.776e+06 --stopTime=8.64e+06 --stepSize=345.6 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Examples_Combined_ETSHeatRecoveryHeatPump_BuildingTimeSeries_WithDHW_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Examples.Combined.ETSHeatRecoveryHeatPump_BuildingTimeSeries.WithDHW (co-simulation) - fmiVersion: 2.0 - startTime : 7776000.000000 - stopTime : 8640000.000000 - tolerance : 1e-06 - stepSize : 345.6 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp7023okgz/WithDHW-5tmf5k60/temp/0001_WithDHW/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/JBA_All_futu_tendays.mos" LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp7023okgz/WithDHW-5tmf5k60/temp/0001_WithDHW/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/JBA_All_futu_tendays.mos" warning: [fmi2Warning] WithDHW/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68: The following assertion has been violated at time 7776000.000000 ((bui.bui.terUniCoo.hexWetNtu.SHR >= 0.0 and bui.bui.terUniCoo.hexWetNtu.SHR <= 1.0), bui.bui.terUniCoo.hexWetNtu.SHR=-1.948754906176889e-07) --> "Variable violating min/max constraint: 0.0 <= bui.bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -1.94875e-07" warning: [fmi2Warning] WithDHW/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 7776000.000000 ((bui.ets.heaPum.pumCon.eff.yMot >= 0.0), bui.ets.heaPum.pumCon.eff.yMot=-0.004818407369347748) --> "Variable violating min constraint: 0.0 <= bui.ets.heaPum.pumCon.eff.yMot, has value: -0.00481841" warning: [fmi2Warning] WithDHW/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 7776000.000000 ((bui.ets.heaPum.pumEva.eff.yMot >= 0.0), bui.ets.heaPum.pumEva.eff.yMot=-7.193257446381015e-15) --> "Variable violating min constraint: 0.0 <= bui.ets.heaPum.pumEva.eff.yMot, has value: -7.19326e-15" info: Result file: Buildings_13_Buildings_DHC_Examples_Combined_ETSHeatRecoveryHeatPump_BuildingTimeSeries_WithDHW_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable WithDHW.bui.bui.filNam will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.bui.bui.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.bui.loa.tableName will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.bui.datHeaPum.datHea.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.datHeaPum.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.datHeaPum.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.dat.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumCoo.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.datTab.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.delimiter will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.fileName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.tableName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.delimiter will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.fileName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.tableName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.filNam will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.bui.loaEleNonHva.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.bui.loaEleNonHva.tableName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.filNam will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.wea.filNam will not be stored in the result file, because the signal type is not supported info: 3 warnings info: 0 errors