(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.TwoIdenticalZones_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_TwoIdenticalZones_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=604800 --stepSize=240.669 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_TwoIdenticalZones_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.TwoIdenticalZones (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 604800.000000 - tolerance : 1e-06 - stepSize : 240.669 LOG_STDOUT | info | ... loading "EnergyPlus" from "/tmp/tmpj4xbu2jz/TwoIdenticalZones-pl2j1mfc/temp/0001_TwoIdenticalZones/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Resources/Data/ThermalZones/EnergyPlus_24_2_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 06:57 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output TwoIdenticalZones.inf1.y has in Modelica the unit 1. info: Result file: ../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.TwoIdenticalZones_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter TwoIdenticalZones.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.inf1.key will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.inf1.name will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.zon1.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalZones.zon2.zoneName will not be stored in the result file, because the signal type is not supported Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.25sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used.