(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=345600 --stepSize=126.27 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 345600.000000 - tolerance : 1e-06 - stepSize : 126.27 warning: [fmi2Warning] AllElectricCWStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((pla.pumChiWat.pum.etaHyd >= 0.0), pla.pumChiWat.pum.etaHyd=-2.319558095679104e-43) --> "Variable violating min constraint: 0.0 <= pla.pumChiWat.pum.etaHyd, has value: -2.31956e-43" warning: [fmi2Warning] AllElectricCWStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((pla.pumHeaWat.pum.etaHyd >= 0.0), pla.pumHeaWat.pum.etaHyd=-1.178086321256335e-41) --> "Variable violating min constraint: 0.0 <= pla.pumHeaWat.pum.etaHyd, has value: -1.17809e-41" warning: [fmi2Warning] AllElectricCWStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((pla.pumConWatCon.pum.etaHyd >= 0.0), pla.pumConWatCon.pum.etaHyd=-5.672572496248868e-46) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCon.pum.etaHyd, has value: -5.67257e-46" warning: [fmi2Warning] AllElectricCWStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((pla.pumConWatEva.pum.etaHyd >= 0.0), pla.pumConWatEva.pum.etaHyd=-1.692189881860027e-42) --> "Variable violating min constraint: 0.0 <= pla.pumConWatEva.pum.etaHyd, has value: -1.69219e-42" info: Result file: ../Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter AllElectricCWStorage.pla.heaPum.heaPum.aleMes.message will not be stored in the result file, because the signal type is not supported info: Parameter AllElectricCWStorage.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: 4 warnings info: 0 errors