(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_Applications_DataCenters_ChillerCooled_Examples_IntegratedPrimaryLoadSideEconomizer_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_Applications_DataCenters_ChillerCooled_Examples_IntegratedPrimaryLoadSideEconomizer_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 warning: [fmi2Warning] IntegratedPrimaryLoadSideEconomizer/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/CoolingTowers/YorkCalc.mo:28: The following assertion has been violated at time 0.000000 ((cooTow[1].FRWat >= 0.0 and cooTow[1].FRWat <= 1.0), cooTow[1].FRWat=1.000394843006158) --> "Variable violating min/max constraint: 0.0 <= cooTow[1].FRWat <= 1.0, has value: 1.00039" warning: [fmi2Warning] IntegratedPrimaryLoadSideEconomizer/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/CoolingTowers/YorkCalc.mo:28: The following assertion has been violated at time 0.000000 ((cooTow[2].FRWat >= 0.0 and cooTow[2].FRWat <= 1.0), cooTow[2].FRWat=1.000394843006158) --> "Variable violating min/max constraint: 0.0 <= cooTow[2].FRWat <= 1.0, has value: 1.00039" warning: [fmi2Warning] IntegratedPrimaryLoadSideEconomizer/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((ahu.fan.etaHyd >= 0.0), ahu.fan.etaHyd=-4.595447847516819e-21) --> "Variable violating min constraint: 0.0 <= ahu.fan.etaHyd, has value: -4.59545e-21" info: Result file: ../Buildings_12_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter IntegratedPrimaryLoadSideEconomizer.CWPumCon.combiTable1Ds.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.CWPumCon.combiTable1Ds.fileName will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.CWPumCon.combiTable1Ds.tableName will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.chiStaCon.combiTable1Ds.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.chiStaCon.combiTable1Ds.fileName will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.chiStaCon.combiTable1Ds.tableName will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.varSpeCon.combiTable1Ds.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.varSpeCon.combiTable1Ds.fileName will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.varSpeCon.combiTable1Ds.tableName will not be stored in the result file, because the signal type is not supported info: Parameter IntegratedPrimaryLoadSideEconomizer.weaData.filNam will not be stored in the result file, because the signal type is not supported info: 3 warnings info: 0 errors