(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=11000 --stepSize=4.4 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 11000.000000 - tolerance : 1e-06 - stepSize : 4.4 warning: [fmi2Warning] FluidStorageChargeDischargeProfile/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Technologies/ThermalStorages/BaseClasses/BuoyancyModels/Buoyancy1.mo:11: The following assertion has been violated during initialization at time 0.000000 ((false)) --> "The number of nodes used nEle is out of the validated range (between 4 and 40), see Info section of the selected buoyancy model." warning: [fmi2Warning] FluidStorageChargeDischargeProfile/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28: The following assertion has been violated during initialization at time 0.000000 ((not senTem_bottom.warnAboutOnePortConnection), senTem_bottom.warnAboutOnePortConnection=true) --> "Sensor FluidStorageChargeDischargeProfile.senTem_bottom can lead to numerical problems if connected to a scalar fluid port. Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. See BuildingSystems.Fluid.Sensors.UsersGuide for more information. To disable this warning, set 'warnAboutOnePortConnection = false' in FluidStorageChargeDischargeProfile.senTem_bottom." info: Result file: BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: 2 warnings info: 0 errors