(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_OMSimulator-cs-cvode_fmu --startTime=1.0368e+07 --stopTime=1.07136e+07 --stepSize=138.24 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage (co-simulation) - fmiVersion: 2.0 - startTime : 10368000.000000 - stopTime : 10713600.000000 - tolerance : 1e-06 - stepSize : 138.24 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmppmjyntwp/BigCollectorInstallationWithStorage-bt7eptma/temp/0001_BigCollectorInstallationWithStorage/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" warning: [fmi2Warning] BigCollectorInstallationWithStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389: The following assertion has been violated during initialization at time 10368000.000000 ((pump1.nominalValuesDefineDefaultPressureCurve), pump1.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." warning: [fmi2Warning] BigCollectorInstallationWithStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389: The following assertion has been violated during initialization at time 10368000.000000 ((pump2.nominalValuesDefineDefaultPressureCurve), pump2.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." warning: [fmi2Warning] BigCollectorInstallationWithStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28: The following assertion has been violated during initialization at time 10368000.000000 ((not senTem1.warnAboutOnePortConnection), senTem1.warnAboutOnePortConnection=true) --> "Sensor BigCollectorInstallationWithStorage.senTem1 can lead to numerical problems if connected to a scalar fluid port. Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. See BuildingSystems.Fluid.Sensors.UsersGuide for more information. To disable this warning, set 'warnAboutOnePortConnection = false' in BigCollectorInstallationWithStorage.senTem1." info: Result file: BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Variable BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter BigCollectorInstallationWithStorage.weatherData.weatherData.filNam will not be stored in the result file, because the signal type is not supported info: Parameter BigCollectorInstallationWithStorage.weatherData.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable BigCollectorInstallationWithStorage.weatherData.weatherData.tabNam will not be stored in the result file, because the signal type is not supported info: 3 warnings info: 0 errors