(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Fluid_Movers_Validation_PowerSimplified_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=200 --stepSize=0.08 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Fluid_Movers_Validation_PowerSimplified_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : BuildingSystems.Fluid.Movers.Validation.PowerSimplified (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 200.000000 - tolerance : 1e-06 - stepSize : 0.08 warning: [fmi2Warning] PowerSimplified/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389: The following assertion has been violated during initialization at time 0.000000 ((pump_dp.nominalValuesDefineDefaultPressureCurve), pump_dp.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in PowerSimplified.pump_dp: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." warning: [fmi2Warning] PowerSimplified/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389: The following assertion has been violated during initialization at time 0.000000 ((pump_m_flow.nominalValuesDefineDefaultPressureCurve), pump_m_flow.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in PowerSimplified.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: Result file: BuildingSystems_BuildingSystems_Fluid_Movers_Validation_PowerSimplified_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: 2 warnings info: 0 errors