(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Fluid_Interfaces_Examples_PrescribedOutlet_Water_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1200 --stepSize=0.48 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Fluid_Interfaces_Examples_PrescribedOutlet_Water_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : BuildingSystems.Fluid.Interfaces.Examples.PrescribedOutlet_Water (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1200.000000 - tolerance : 1e-06 - stepSize : 0.48 info: Result file: BuildingSystems_BuildingSystems_Fluid_Interfaces_Examples_PrescribedOutlet_Water_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter PrescribedOutlet_Water.setCooLimPow.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PrescribedOutlet_Water.setCooLimPow.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PrescribedOutlet_Water.setCooLimPow.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PrescribedOutlet_Water.setHeaCooUnl.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PrescribedOutlet_Water.setHeaCooUnl.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PrescribedOutlet_Water.setHeaCooUnl.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PrescribedOutlet_Water.setHeaHigPow.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PrescribedOutlet_Water.setHeaHigPow.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PrescribedOutlet_Water.setHeaHigPow.tableName will not be stored in the result file, because the signal type is not supported