(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem1_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=12614.4 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem1_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : BuildingSystems.Applications.SolarThermalSystems.SolarThermalSystem1 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 31536000.000000 - tolerance : 1e-06 - stepSize : 12614.4 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmpyqsiafua/SolarThermalSystem1-l6gak9t0/temp/0001_SolarThermalSystem1/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Egypt_ElGouna.txt" info: Result file: BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem1_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter SolarThermalSystem1.weatherData.weatherData.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Variable SolarThermalSystem1.weatherData.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter SolarThermalSystem1.weatherData.weatherData.filNam will not be stored in the result file, because the signal type is not supported info: Parameter SolarThermalSystem1.weatherData.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable SolarThermalSystem1.weatherData.weatherData.tabNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 26683.101995 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.51093740348, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.5 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 26683.101995 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.51093740354, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.5 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 26683.101995 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.51093740354, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.5 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 26683.101995 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.51093740354, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.5 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 27398.288077 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.80188190757, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 27398.288077 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.8018819078, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 27398.288077 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.8018819078, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 27398.288077 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.8018819078, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 28022.580161 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.60515892983, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.6 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 28022.580161 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.60515893006, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.6 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 28022.580161 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.60515893006, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.6 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 28022.580161 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.60515893006, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.6 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 28576.698573 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.93272866006, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.9 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 28576.698573 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.93272866029, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.9 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 28576.698573 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.93272866029, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.9 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 28576.698573 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56397.93272866029, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56397.9 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29082.389041 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.19234581199, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.2 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29082.389041 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.19234581199, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.2 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29082.389041 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.19234581199, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.2 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29082.389041 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.19234581199, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.2 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29551.838715 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.52999348927, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.5 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29551.838715 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.52999348927, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.5 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29551.838715 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.52999348927, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.5 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29551.838715 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.52999348927, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.5 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29992.799332 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.70281265548, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.7 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29992.799332 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.70281265571, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.7 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29992.799332 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.70281265571, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.7 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 29992.799332 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.70281265571, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.7 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 30410.637065 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.8640875275, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.9 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 30410.637065 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.8640875275, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.9 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 30410.637065 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.8640875275, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.9 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 30410.637065 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.8640875275, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.9 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 30809.200894 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.81134734506, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 30809.200894 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.81134734506, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 30809.200894 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.81134734506, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 30809.200894 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.81134734506, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31191.261686 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.00020148174, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31191.261686 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.00020148174, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31191.261686 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.00020148174, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31191.261686 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.00020148174, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31558.824071 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.11697145709, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.1 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31558.824071 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.11697145709, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.1 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31558.824071 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.11697145709, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.1 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31558.824071 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.11697145709, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.1 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31913.643658 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.24686086562, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.2 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31913.643658 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.24686086562, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.2 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31913.643658 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.24686086562, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.2 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 31913.643658 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.24686086562, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.2 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32255.003232 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.79873074358, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32255.003232 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.79873074358, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32255.003232 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.79873074358, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32255.003232 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56398.79873074358, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56398.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32558.765694 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.718954893, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.7 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32558.765694 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.718954893, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.7 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32558.765694 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.718954893, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.7 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32558.765694 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.718954893, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.7 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32763.174296 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.78514865402, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32763.174296 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.78514865402, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32763.174296 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.78514865402, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 32763.174296 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.78514865402, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 37843.200000 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.79614483146, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 37843.200000 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.79614483146, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 37843.200000 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.79614483146, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] SolarThermalSystem1/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93: The following assertion has been violated at time 37843.200000 (((-pump.dp) <= pump.dpMax), pump.dp=-56399.79614483146, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. This can happen if the model forces a high mass flow rate through a closed actuator, or if the performance record is unreasonable. Please verify your model, and consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] SolarThermalSystem1/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "SolarThermalSystem1.root.SolarThermalSystem1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 37843.200000 | | | | (((-pump.dp) <= pump.dpMax), pump.dp=-56399.79614483146, pump.dpMax=40000) --> "In SolarThermalSystem1.pump: Model operates with head -dp = 56399.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem1.pump.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 3 errors