(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_PowerSimplified_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=200 --stepSize=0.08 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_PowerSimplified_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : BuildSysPro.IBPSA.Fluid.Movers.Validation.PowerSimplified (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 200.000000 - tolerance : 1e-06 - stepSize : 0.08 warning: [fmi2Warning] PowerSimplified/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387: The following assertion has been violated during initialization at time 0.000000 ((pump_dp.nominalValuesDefineDefaultPressureCurve), pump_dp.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning: You are using a flow or pressure controlled mover with the default pressure curve. This leads to approximate calculations of the electrical power consumption. Add the correct pressure curve in the record per to obtain an accurate computation. Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." warning: [fmi2Warning] PowerSimplified/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387: The following assertion has been violated during initialization at time 0.000000 ((pump_m_flow.nominalValuesDefineDefaultPressureCurve), pump_m_flow.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning: You are using a flow or pressure controlled mover with the default pressure curve. This leads to approximate calculations of the electrical power consumption. Add the correct pressure curve in the record per to obtain an accurate computation. Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: Result file: BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_PowerSimplified_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: 2 warnings info: 0 errors