(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=600 --stepSize=0.24 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : BuildSysPro.IBPSA.Fluid.Movers.Preconfigured.Validation.ControlledFlowMachinePreconfigured (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 600.000000 - tolerance : 1e-06 - stepSize : 0.24 warning: [fmi2Warning] ControlledFlowMachinePreconfigured/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:90: The following assertion has been violated at time 0.000000 ((fan1.etaHyd >= 0.0), fan1.etaHyd=-2.323400365657458e-26) --> "Variable violating min constraint: 0.0 <= fan1.etaHyd, has value: -2.3234e-26" warning: [fmi2Warning] ControlledFlowMachinePreconfigured/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PowerInterface.mo:46: The following assertion has been violated at time 0.000000 ((fan1.heaDis.etaHyd >= 0.0), fan1.heaDis.etaHyd=-4.337014015893922e-22) --> "Variable violating min constraint: 0.0 <= fan1.heaDis.etaHyd, has value: -4.33701e-22" warning: [fmi2Warning] ControlledFlowMachinePreconfigured/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:301: The following assertion has been violated at time 0.000000 ((fan3.eff.yMot >= 0.0), fan3.eff.yMot=-1.094239811481895e-25) --> "Variable violating min constraint: 0.0 <= fan3.eff.yMot, has value: -1.09424e-25" warning: [fmi2Warning] ControlledFlowMachinePreconfigured/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:90: The following assertion has been violated at time 0.000000 ((fan4.etaHyd >= 0.0), fan4.etaHyd=-2.323400365657458e-26) --> "Variable violating min constraint: 0.0 <= fan4.etaHyd, has value: -2.3234e-26" warning: [fmi2Warning] ControlledFlowMachinePreconfigured/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PowerInterface.mo:46: The following assertion has been violated at time 0.000000 ((fan4.heaDis.etaHyd >= 0.0), fan4.heaDis.etaHyd=-4.337014015893922e-22) --> "Variable violating min constraint: 0.0 <= fan4.heaDis.etaHyd, has value: -4.33701e-22" info: Result file: BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: 5 warnings info: 0 errors