(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Examples_MoverStages_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Examples_MoverStages_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : BuildSysPro.IBPSA.Fluid.Movers.Examples.MoverStages (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.0004 warning: [fmi2Warning] MoverStages/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387: The following assertion has been violated during initialization at time 0.000000 ((pump_m_flow.nominalValuesDefineDefaultPressureCurve), pump_m_flow.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning: You are using a flow or pressure controlled mover with the default pressure curve. This leads to approximate calculations of the electrical power consumption. Add the correct pressure curve in the record per to obtain an accurate computation. Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." warning: [fmi2Warning] MoverStages/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420: The following assertion has been violated during initialization at time 0.000000 ((false)) --> "*** Warning in MoverStages.pump_m_flow: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. This requires that per.pressure be provided. Because it is not, the model will override this setting and use .NotProvided instead." warning: [fmi2Warning] MoverStages/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 ((false)) --> "*** Warning in MoverStages.pump_m_flow: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio or .GenericCurve. This requires that per.WMot_nominal be provided or at least per.pressure be provided so that per.WMot_nominal can be estimated. Because neither is provided, the model will override this setting and use .NotProvided instead." info: Result file: BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Examples_MoverStages_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter MoverStages.integerTable.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter MoverStages.integerTable.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter MoverStages.integerTable.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: 3 warnings info: 0 errors