(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Examples_SimpleHouse_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=12614.4 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildSysPro_BuildSysPro_IBPSA_Fluid_Examples_SimpleHouse_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : BuildSysPro.IBPSA.Fluid.Examples.SimpleHouse (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 31536000.000000 - tolerance : 1e-06 - stepSize : 12614.4 warning: [fmi2Warning] SimpleHouse/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420: The following assertion has been violated during initialization at time 0.000000 ((false)) --> "*** Warning in SimpleHouse.pump: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. This requires that per.pressure be provided. Because it is not, the model will override this setting and use .NotProvided instead." warning: [fmi2Warning] SimpleHouse/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 ((false)) --> "*** Warning in SimpleHouse.pump: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio or .GenericCurve. This requires that per.WMot_nominal be provided or at least per.pressure be provided so that per.WMot_nominal can be estimated. Because neither is provided, the model will override this setting and use .NotProvided instead." warning: [fmi2Warning] SimpleHouse/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420: The following assertion has been violated during initialization at time 0.000000 ((false)) --> "*** Warning in SimpleHouse.fan: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. This requires that per.pressure be provided. Because it is not, the model will override this setting and use .NotProvided instead." warning: [fmi2Warning] SimpleHouse/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429: The following assertion has been violated during initialization at time 0.000000 ((false)) --> "*** Warning in SimpleHouse.fan: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio or .GenericCurve. This requires that per.WMot_nominal be provided or at least per.pressure be provided so that per.WMot_nominal can be estimated. Because neither is provided, the model will override this setting and use .NotProvided instead." info: Result file: BuildSysPro_BuildSysPro_IBPSA_Fluid_Examples_SimpleHouse_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter SimpleHouse.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: 4 warnings info: 0 errors