(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Examples_ThrottlePump_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=600 --stepSize=0.24 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Systems_HydraulicModules_Examples_ThrottlePump_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : AixLib.Systems.HydraulicModules.Examples.ThrottlePump (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 600.000000 - tolerance : 1e-06 - stepSize : 0.24 warning: [fmi2Warning] ThrottlePump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6: The following assertion has been violated at time 0.000000 ((ThrottlePump.PumpInterface.pump.eff.powEu.P[1] >= 0.0), ThrottlePump.PumpInterface.pump.eff.powEu.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" warning: [fmi2Warning] ThrottlePump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7: The following assertion has been violated at time 0.000000 ((ThrottlePump.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0), ThrottlePump.PumpInterface.pump.eff.powEu_internal.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" warning: [fmi2Warning] ThrottlePump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100: The following assertion has been violated at time 0.000000 ((ThrottlePump.PumpInterface.pump.eta >= 0.0), ThrottlePump.PumpInterface.pump.eta=-6.241671871019021e-45) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eta, has value: -6.24167e-45" warning: [fmi2Warning] ThrottlePump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46: The following assertion has been violated at time 0.000000 ((ThrottlePump.PumpInterface.pump.heaDis.etaHyd >= 0.0), ThrottlePump.PumpInterface.pump.heaDis.etaHyd=-5.234225976490497e-42) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.heaDis.etaHyd, has value: -5.23423e-42" warning: [fmi2Warning] ThrottlePump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 0.000000 ((ThrottlePump.PumpInterface.pump.eff.yMot >= 0.0), ThrottlePump.PumpInterface.pump.eff.yMot=-6.962503334511917e-47) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eff.yMot, has value: -6.9625e-47" info: Result file: AixLib_AixLib_Systems_HydraulicModules_Examples_ThrottlePump_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable ThrottlePump.ThrottlePump.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ThrottlePump.ThrottlePump.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ThrottlePump.ThrottlePump.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ThrottlePump.ThrottlePump.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ThrottlePump.ThrottlePump.pipeModel will not be stored in the result file, because the signal type is not supported info: 5 warnings info: 0 errors