(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Examples_Injection_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=800 --stepSize=0.32 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Systems_HydraulicModules_Examples_Injection_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : AixLib.Systems.HydraulicModules.Examples.Injection (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 800.000000 - tolerance : 1e-06 - stepSize : 0.32 warning: [fmi2Warning] Injection/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7: The following assertion has been violated at time 0.000000 ((Injection.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0), Injection.PumpInterface.pump.eff.powEu_internal.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" warning: [fmi2Warning] Injection/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6: The following assertion has been violated at time 0.000000 ((Injection.PumpInterface.pump.eff.powEu.P[1] >= 0.0), Injection.PumpInterface.pump.eff.powEu.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" warning: [fmi2Warning] Injection/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100: The following assertion has been violated at time 0.000000 ((Injection.PumpInterface.pump.eta >= 0.0), Injection.PumpInterface.pump.eta=-1.339738291700933e-30) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eta, has value: -1.33974e-30" warning: [fmi2Warning] Injection/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46: The following assertion has been violated at time 0.000000 ((Injection.PumpInterface.pump.heaDis.etaHyd >= 0.0), Injection.PumpInterface.pump.heaDis.etaHyd=-1.123495933946807e-27) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.heaDis.etaHyd, has value: -1.1235e-27" warning: [fmi2Warning] Injection/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 0.000000 ((Injection.PumpInterface.pump.eff.yMot >= 0.0), Injection.PumpInterface.pump.eff.yMot=-1.494460541357833e-32) --> "Variable violating min constraint: 0.0 <= Injection.PumpInterface.pump.eff.yMot, has value: -1.49446e-32" info: Result file: AixLib_AixLib_Systems_HydraulicModules_Examples_Injection_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable Injection.Injection.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipe7.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipe8.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipe9.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Injection.Injection.pipeModel will not be stored in the result file, because the signal type is not supported info: 5 warnings info: 0 errors