(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Examples_ERC_ExperimentalHall_CoolingCircuit_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Systems_HydraulicModules_Examples_ERC_ExperimentalHall_CoolingCircuit_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : AixLib.Systems.HydraulicModules.Examples.ERC_ExperimentalHall_CoolingCircuit (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3600.000000 - tolerance : 1e-06 - stepSize : 1.44 warning: [fmi2Warning] ERC_ExperimentalHall_CoolingCircuit/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7: The following assertion has been violated at time 0.000000 ((unmixed.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0), unmixed.PumpInterface.pump.eff.powEu_internal.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= unmixed.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" warning: [fmi2Warning] ERC_ExperimentalHall_CoolingCircuit/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6: The following assertion has been violated at time 0.000000 ((unmixed.PumpInterface.pump.eff.powEu.P[1] >= 0.0), unmixed.PumpInterface.pump.eff.powEu.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= unmixed.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" warning: [fmi2Warning] ERC_ExperimentalHall_CoolingCircuit/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7: The following assertion has been violated at time 0.000000 ((unmixedThrottle.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0), unmixedThrottle.PumpInterface.pump.eff.powEu_internal.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= unmixedThrottle.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" warning: [fmi2Warning] ERC_ExperimentalHall_CoolingCircuit/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6: The following assertion has been violated at time 0.000000 ((unmixedThrottle.PumpInterface.pump.eff.powEu.P[1] >= 0.0), unmixedThrottle.PumpInterface.pump.eff.powEu.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= unmixedThrottle.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" warning: [fmi2Warning] ERC_ExperimentalHall_CoolingCircuit/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7: The following assertion has been violated at time 0.000000 ((admix.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0), admix.PumpInterface.pump.eff.powEu_internal.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= admix.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" warning: [fmi2Warning] ERC_ExperimentalHall_CoolingCircuit/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6: The following assertion has been violated at time 0.000000 ((admix.PumpInterface.pump.eff.powEu.P[1] >= 0.0), admix.PumpInterface.pump.eff.powEu.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= admix.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" info: Result file: AixLib_AixLib_Systems_HydraulicModules_Examples_ERC_ExperimentalHall_CoolingCircuit_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable ERC_ExperimentalHall_CoolingCircuit.admix.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.admix.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.admix.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.admix.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.admix.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.admix.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.admix.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.simpleConsumer.functionality will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.simpleConsumer1.functionality will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.simpleConsumer2.functionality will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixed.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixed.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixed.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixed.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixedThrottle.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixedThrottle.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixedThrottle.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixedThrottle.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ERC_ExperimentalHall_CoolingCircuit.unmixedThrottle.pipeModel will not be stored in the result file, because the signal type is not supported info: 6 warnings info: 0 errors