Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001301/0.001301, allocations: 101.3 kB / 19.73 MB, free: 2.133 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001494/0.001494, allocations: 220.4 kB / 23.03 MB, free: 4.945 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.482/1.482, allocations: 230.6 MB / 256.8 MB, free: 7.777 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.7921/0.7921, allocations: 100.3 MB / 413.6 MB, free: 3.406 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002433/0.002433, allocations: 86.98 kB / 0.564 GB, free: 35.89 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1546/0.1571, allocations: 74.46 MB / 0.6367 GB, free: 7.422 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling): time 0.6847/0.8417, allocations: 239.1 MB / 0.8703 GB, free: 12.7 MB / 0.6231 GB Notification: Performance of NFInst.instExpressions: time 0.01122/0.853, allocations: 5.067 MB / 0.8752 GB, free: 8.469 MB / 0.6231 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.002413/0.8554, allocations: 53.44 kB / 0.8753 GB, free: 8.441 MB / 0.6231 GB Notification: Performance of NFTyping.typeComponents: time 0.003544/0.8589, allocations: 0.719 MB / 0.876 GB, free: 7.906 MB / 0.6231 GB Notification: Performance of NFTyping.typeBindings: time 0.01155/0.8705, allocations: 3.252 MB / 0.8791 GB, free: 4.641 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.001304/0.8718, allocations: 352.5 kB / 0.8795 GB, free: 4.301 MB / 0.6231 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.271110062953085] Failed to read output from testmodel.py, exit status != 0: 0.8789096790133044 0.897996287 -1.0 Calling exit ...