Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.9128/0.9128, allocations: 153.8 MB / 173.4 MB, free: 4.855 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding,fileNamePrefix="ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_Islanding",fmuType="cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding,fileNamePrefix="ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_Islanding",fmuType="cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.000485/0.000485, allocations: 11.98 kB / 250.6 MB, free: 4.379 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1849/0.1854, allocations: 33.35 MB / 283.9 MB, free: 1.723 MB / 222.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding): time 1.905/2.091, allocations: 319.5 MB / 0.5892 GB, free: 13.61 MB / 478.1 MB Notification: Performance of NFInst.instExpressions: time 0.2298/2.32, allocations: 180.8 MB / 0.7658 GB, free: 3.992 MB / 0.6231 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.003959/2.324, allocations: 111.1 kB / 0.7659 GB, free: 3.883 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceP.mo:59:3-60:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkP.mo:47:3-48:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/TwoPhaseCavity.mo:182:3-184:57:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/TwoPhaseCavity.mo:185:3-187:61:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/TwoPhaseCavity.mo:200:3-201:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicWaterHeater.mo:98:3-99:65:writable] Warning: Connector C1vap is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicWaterHeater.mo:100:3-102:16:writable] Warning: Connector C2ex is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicWaterHeater.mo:103:3-104:76:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicWaterHeater.mo:105:3-106:74:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicWaterHeater.mo:111:3-112:74:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/Sink.mo:40:3-41:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceP.mo:59:3-60:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/RefQ.mo:11:3-12:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/RefQ.mo:13:3-14:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/IdealCheckValve.mo:22:3-23:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/IdealCheckValve.mo:24:3-25:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/LumpedStraightPipe.mo:54:3-55:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/LumpedStraightPipe.mo:56:3-57:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.003536/2.328, allocations: 0.9713 MB / 0.7668 GB, free: 2.91 MB / 0.6231 GB Notification: Performance of NFTyping.typeBindings: time 0.007397/2.335, allocations: 2.334 MB / 0.7691 GB, free: 0.5625 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/Fluid/derDensity_derP_derh.mo:63:5-63:84:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.0502/2.386, allocations: 17.36 MB / 0.7861 GB, free: 15.2 MB / 0.6544 GB Notification: Performance of NFFlatten.flatten: time 0.03432/2.42, allocations: 31.36 MB / 0.8167 GB, free: 15.77 MB / 0.6856 GB Notification: Performance of NFFlatten.resolveConnections: time 0.01655/2.436, allocations: 9.881 MB / 0.8263 GB, free: 5.816 MB / 0.6856 GB Notification: Performance of NFEvalConstants.evaluate: time 0.4191/2.856, allocations: 9.17 MB / 0.8353 GB, free: 28.34 MB / 0.6856 GB Notification: Performance of NFSimplifyModel.simplify: time 0.02229/2.878, allocations: 10.9 MB / 0.8459 GB, free: 28.33 MB / 0.6856 GB Notification: Performance of NFPackage.collectConstants: time 0.01325/2.891, allocations: 2.817 MB / 0.8487 GB, free: 28.33 MB / 0.6856 GB Notification: Performance of NFFlatten.collectFunctions: time 0.05791/2.949, allocations: 26.38 MB / 0.8744 GB, free: 28.33 MB / 0.6856 GB Notification: Performance of NFScalarize.scalarize: time 0.01404/2.963, allocations: 8.055 MB / 0.8823 GB, free: 28.33 MB / 0.6856 GB Notification: Performance of NFVerifyModel.verify: time 0.02389/2.987, allocations: 8.58 MB / 0.8907 GB, free: 27.23 MB / 0.6856 GB Notification: Performance of NFConvertDAE.convert: time 0.06541/3.052, allocations: 39.16 MB / 0.9289 GB, free: 11.5 MB / 0.6856 GB Notification: Performance of FrontEnd - DAE generated: time 7.073e-06/3.052, allocations: 0 / 0.9289 GB, free: 11.5 MB / 0.6856 GB Notification: Performance of FrontEnd: time 2.214e-06/3.052, allocations: 1.031 kB / 0.9289 GB, free: 11.5 MB / 0.6856 GB Notification: Performance of Transformations before backend: time 0.001069/3.053, allocations: 0.6562 kB / 0.9289 GB, free: 11.5 MB / 0.6856 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 3465 * Number of variables: 3465 Notification: Performance of Generate backend data structure: time 0.0811/3.135, allocations: 19.88 MB / 0.9483 GB, free: 15.51 MB / 0.7012 GB Notification: Performance of prepare preOptimizeDAE: time 5.275e-05/3.135, allocations: 8.031 kB / 0.9484 GB, free: 15.5 MB / 0.7012 GB Notification: Performance of preOpt introduceOutputRealDerivatives (simulation): time 0.0004729/3.135, allocations: 351.5 kB / 0.9487 GB, free: 15.16 MB / 0.7012 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.01096/3.146, allocations: 1.801 MB / 0.9504 GB, free: 13.34 MB / 0.7012 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02035/3.166, allocations: 2.391 MB / 0.9528 GB, free: 10.97 MB / 0.7012 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0219/3.188, allocations: 7.3 MB / 0.9599 GB, free: 3.977 MB / 0.7012 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.006116/3.194, allocations: 5.406 MB / 0.9652 GB, free: 13.58 MB / 0.7169 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.009278/3.204, allocations: 1.419 MB / 0.9666 GB, free: 12.16 MB / 0.7169 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.07995/3.284, allocations: 26.52 MB / 0.9925 GB, free: 0.5 MB / 0.7325 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001079/3.285, allocations: 60.38 kB / 0.9925 GB, free: 488 kB / 0.7325 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.009227/3.294, allocations: 0.5621 MB / 0.9931 GB, free: 15.92 MB / 0.7481 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0004215/3.294, allocations: 355.9 kB / 0.9934 GB, free: 15.57 MB / 0.7481 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.1709/3.465, allocations: 72.95 MB / 1.065 GB, free: 6.91 MB / 0.8106 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.4604/3.926, allocations: 91.36 MB / 1.154 GB, free: 443.8 MB / 0.8887 GB Notification: Performance of preOpt comSubExp (simulation): time 0.08596/4.012, allocations: 32.66 MB / 1.186 GB, free: 437.7 MB / 0.8887 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.02527/4.037, allocations: 12.21 MB / 1.198 GB, free: 432.5 MB / 0.8887 GB Notification: Performance of preOpt evalFunc (simulation): time 1.002/5.039, allocations: 351.1 MB / 1.541 GB, free: 102.8 MB / 0.8887 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.03822/5.077, allocations: 14.63 MB / 1.555 GB, free: 88.03 MB / 0.8887 GB Notification: Performance of pre-optimization done (n=1628): time 3.133e-05/5.077, allocations: 4 kB / 1.555 GB, free: 88.03 MB / 0.8887 GB Notification: Performance of matching and sorting (n=1629): time 0.7838/5.861, allocations: 120.3 MB / 1.672 GB, free: 438.8 MB / 0.8887 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0001928/5.861, allocations: 498.4 kB / 1.673 GB, free: 438.3 MB / 0.8887 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.006574/5.868, allocations: 5.223 MB / 1.678 GB, free: 434 MB / 0.8887 GB Notification: Performance of collectPreVariables (initialization): time 0.005013/5.873, allocations: 301.7 kB / 1.678 GB, free: 433.7 MB / 0.8887 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/LumpedStraightPipe.mo:10:3-11:71:writable] Warning: The parameter PressureLoss_Steam.lambda has fixed = false and a binding equation PressureLoss_Steam.lambda = 0.03, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicWaterHeater.mo:38:3-38:111:writable] Warning: The parameter WaterHeating.COP0l has fixed = false and a binding equation WaterHeating.COP0l = 1.23, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:6:3-7:43:writable] Warning: The parameter ControlValve_eau.Cvmax has fixed = false and a binding equation ControlValve_eau.Cvmax = 354.534, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. Notification: Performance of collectInitialEqns (initialization): time 0.003078/5.876, allocations: 4.157 MB / 1.682 GB, free: 430.2 MB / 0.8887 GB Notification: Performance of collectInitialBindings (initialization): time 0.009008/5.885, allocations: 6.136 MB / 1.688 GB, free: 424.7 MB / 0.8887 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.01692/5.902, allocations: 3.704 MB / 1.692 GB, free: 421.5 MB / 0.8887 GB Notification: Performance of setup shared object (initialization): time 4.361e-05/5.902, allocations: 301.1 kB / 1.692 GB, free: 421.2 MB / 0.8887 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.02368/5.925, allocations: 11.94 MB / 1.704 GB, free: 410.1 MB / 0.8887 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.02757/5.953, allocations: 16.25 MB / 1.72 GB, free: 392.2 MB / 0.8887 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 1.315/7.268, allocations: 241.3 MB / 1.955 GB, free: 150.3 MB / 0.8887 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001847/7.268, allocations: 35.47 kB / 1.955 GB, free: 150.3 MB / 0.8887 GB Notification: Performance of matching and sorting (n=2352) (initialization): time 0.1216/7.39, allocations: 41.89 MB / 1.996 GB, free: 108.3 MB / 0.8887 GB Notification: Performance of prepare postOptimizeDAE: time 0.000163/7.39, allocations: 107.4 kB / 1.996 GB, free: 108.2 MB / 0.8887 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001691/7.39, allocations: 116.1 kB / 1.996 GB, free: 108.1 MB / 0.8887 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.8218/8.212, allocations: 324.2 MB / 2.313 GB, free: 224.2 MB / 0.8887 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.009556/8.221, allocations: 1.857 MB / 2.315 GB, free: 222.8 MB / 0.8887 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.1118/8.333, allocations: 44.21 MB / 2.358 GB, free: 189.3 MB / 0.8887 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01828/8.352, allocations: 0.8417 MB / 2.359 GB, free: 188.7 MB / 0.8887 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.005719/8.357, allocations: 0.9263 MB / 2.36 GB, free: 187.9 MB / 0.8887 GB Warning: Assuming fixed start value for the following 1 variables: regulation_Niveau.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 3 initial equations are redundant, so they are removed from the initialization system: $DER.WaterHeating.pipe_1.Q[9] = 0.0 $DER.WaterHeating.pipe_1.Q[10] = 0.0 singularPressureLossPurge.T = $START.singularPressureLossPurge.T. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 524 * Number of states: 0 () * Number of discrete variables: 83 ($PRE.regulation_Niveau.pIsat1.Integrateur1.x0,regulation_Niveau.pIsat1.Integrateur1.x0,$PRE.checkValve.touvert,$whenCondition2,$PRE.checkValve.tferme,$whenCondition1,sourceP.C.ftype,WaterHeating.WaterHeating.Cl.ftype,WaterHeating.volumeC.Cs.ftype,sourceP1.C.ftype,WaterHeating.C1.ftype,WaterHeating.volumeD1.Cs3.ftype,WaterHeating.volumeD1.Cs2.ftype,WaterHeating.volumeD1.Cs1.ftype,WaterHeating.volumeD.Cs2.ftype,WaterHeating.volumeD1.fluids[1],WaterHeating.volumeD.Cs3.ftype,WaterHeating.volumeD.Cs1.ftype,WaterHeating.volumeD.fluids[1],WaterHeating.volumeC.Ce2.ftype,WaterHeating.volumeC.fluids[1],WaterHeating.WaterHeating.fluids[1],Puit_condenseur1.fluid,ControlValve_eau.fluid,WaterHeating.pipe_3.fluid,WaterHeating.pipe_1.fluid,WaterHeating.pipe_2.fluid,Puit_condenseur2.fluid,singularPressureLossWaterIn.fluid,singularPressureLossWaterOut.fluid,singularPressureLossPurge.fluid,PressureLoss_Steam.fluid,regulation_Niveau.edge.uL.signal,$PRE.regulation_Niveau.edge.uL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.echelon.yL.signal,checkValve.ouvert,$PRE.checkValve.ouvert,checkValve.touvert,checkValve.tferme,$whenCondition3,sourceP1.fluid1,WaterHeating.volumeD1.fluid1,WaterHeating.volumeD.fluid1,WaterHeating.volumeC.fluid1,sourceP.fluid1,WaterHeating.WaterHeating.Cv.diff_on_2,sourceP.C.diff_on_2,PressureLoss_Steam.C2.diff_on_1,singularPressureLossPurge.C2.diff_on_2,singularPressureLossPurge.C1.diff_on_2,WaterHeating.WaterHeating.Cl.diff_on_1,singularPressureLossPurge.C2.diff_on_1,ControlValve_eau.C2.diff_on_1,singularPressureLossWaterOut.C1.diff_on_2,WaterHeating.volumeC.Cs.diff_on_1,refQ.C2.diff_on_1,singularPressureLossWaterIn.C2.diff_on_1,WaterHeating.volumeD.Ce.diff_on_2,sourceP1.C.diff_on_2,WaterHeating.C1.diff_on_1,WaterHeating.volumeD1.Cs3.diff_on_1,WaterHeating.volumeD1.Cs2.diff_on_1,WaterHeating.volumeD1.Cs1.diff_on_1,WaterHeating.volumeD1.Ce.diff_on_2,WaterHeating.volumeD1.Cs2.diff_on_2,WaterHeating.volumeD1.Cs1.diff_on_2,WaterHeating.volumeD.Cs3.diff_on_1,WaterHeating.volumeD.Cs2.diff_on_1,WaterHeating.volumeD.Cs1.diff_on_1,WaterHeating.volumeD.Cs3.diff_on_2,WaterHeating.volumeC.Ce3.diff_on_2,WaterHeating.volumeC.Ce2.diff_on_2,WaterHeating.volumeC.Ce1.diff_on_2,WaterHeating.volumeC.Ce2.diff_on_1,WaterHeating.pipe_2.C1.diff_on_2,WaterHeating.pipe_2.C2.diff_on_1,WaterHeating.pipe_1.C1.diff_on_2,WaterHeating.pipe_1.C2.diff_on_1,WaterHeating.pipe_3.C1.diff_on_2,WaterHeating.pipe_3.C2.diff_on_1,WaterHeating.WaterHeating.Ce.diff_on_2,WaterHeating.WaterHeating.NbTubT) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1046): * Single equations (assignments): 1037 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 3 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 4 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(1,3,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 3 systems {(1,3), (129,1088), (5,22)} Notification: Performance of prepare postOptimizeDAE: time 0.01405/8.371, allocations: 3.449 MB / 2.363 GB, free: 184.9 MB / 0.8887 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.006824/8.378, allocations: 1.025 MB / 2.364 GB, free: 184.4 MB / 0.8887 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.18/8.558, allocations: 49.08 MB / 2.412 GB, free: 145.8 MB / 0.8887 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.1487/8.707, allocations: 42.18 MB / 2.453 GB, free: 106.2 MB / 0.8887 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0001846/8.707, allocations: 24 kB / 2.453 GB, free: 106.1 MB / 0.8887 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.0005159/8.708, allocations: 79.69 kB / 2.453 GB, free: 106.1 MB / 0.8887 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.2046/8.912, allocations: 63.88 MB / 2.516 GB, free: 42.15 MB / 0.8887 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0001434/8.912, allocations: 4 kB / 2.516 GB, free: 42.15 MB / 0.8887 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.01854/8.931, allocations: 2.958 MB / 2.519 GB, free: 39.19 MB / 0.8887 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.3853/9.316, allocations: 22.64 MB / 2.541 GB, free: 437.7 MB / 0.8887 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.007281/9.323, allocations: 0.7096 MB / 2.542 GB, free: 437.7 MB / 0.8887 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.2392/9.563, allocations: 145.5 MB / 2.684 GB, free: 330 MB / 0.8887 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 7.413e-06/9.563, allocations: 8.625 kB / 2.684 GB, free: 330 MB / 0.8887 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.1986/9.761, allocations: 58.9 MB / 2.741 GB, free: 273.1 MB / 0.8887 GB Notification: Performance of postOpt removeConstants (simulation): time 0.0135/9.775, allocations: 3.81 MB / 2.745 GB, free: 269.3 MB / 0.8887 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.00843/9.783, allocations: 443.7 kB / 2.745 GB, free: 268.9 MB / 0.8887 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.01691/9.8, allocations: 0.6252 MB / 2.746 GB, free: 268.3 MB / 0.8887 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.009826/9.81, allocations: 1.775 MB / 2.748 GB, free: 266.5 MB / 0.8887 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.005739/9.816, allocations: 0.6479 MB / 2.748 GB, free: 265.8 MB / 0.8887 GB Notification: Performance of sorting global known variables: time 0.005482/9.821, allocations: 3.263 MB / 2.751 GB, free: 262.6 MB / 0.8887 GB Notification: Performance of sort global known variables: time 1.1e-07/9.821, allocations: 0 / 2.751 GB, free: 262.6 MB / 0.8887 GB Notification: Performance of remove unused functions: time 0.02917/9.85, allocations: 6.557 MB / 2.758 GB, free: 256.3 MB / 0.8887 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 15 * Number of states: 175 (regulation_Niveau.pT1_1.x,regulation_Niveau.pIsat1.Integrateur1.x,WaterHeating.volumeD1.h,WaterHeating.volumeD1.P,WaterHeating.volumeD.h,WaterHeating.volumeC.h,WaterHeating.volumeC.P,WaterHeating.Wall_2.Tp[10],WaterHeating.Wall_2.Tp[9],WaterHeating.Wall_2.Tp[8],WaterHeating.Wall_2.Tp[7],WaterHeating.Wall_2.Tp[6],WaterHeating.Wall_2.Tp[5],WaterHeating.Wall_2.Tp[4],WaterHeating.Wall_2.Tp[3],WaterHeating.Wall_2.Tp[2],WaterHeating.Wall_2.Tp[1],WaterHeating.pipe_2.h[11],WaterHeating.pipe_2.h[10],WaterHeating.pipe_2.h[9],WaterHeating.pipe_2.h[8],WaterHeating.pipe_2.h[7],WaterHeating.pipe_2.h[6],WaterHeating.pipe_2.h[5],WaterHeating.pipe_2.h[4],WaterHeating.pipe_2.h[3],WaterHeating.pipe_2.h[2],WaterHeating.pipe_2.Q[11],WaterHeating.pipe_2.Q[10],WaterHeating.pipe_2.Q[9],WaterHeating.pipe_2.Q[8],WaterHeating.pipe_2.Q[7],WaterHeating.pipe_2.Q[6],WaterHeating.pipe_2.Q[5],WaterHeating.pipe_2.Q[4],WaterHeating.pipe_2.Q[3],WaterHeating.pipe_2.Q[2],WaterHeating.pipe_2.Q[1],WaterHeating.pipe_2.P[11],WaterHeating.pipe_2.P[10],WaterHeating.pipe_2.P[9],WaterHeating.pipe_2.P[8],WaterHeating.pipe_2.P[7],WaterHeating.pipe_2.P[6],WaterHeating.pipe_2.P[5],WaterHeating.pipe_2.P[4],WaterHeating.pipe_2.P[3],WaterHeating.pipe_2.P[2],WaterHeating.Wall_1.Tp[10],WaterHeating.Wall_1.Tp[9],WaterHeating.Wall_1.Tp[8],WaterHeating.Wall_1.Tp[7],WaterHeating.Wall_1.Tp[6],WaterHeating.Wall_1.Tp[5],WaterHeating.Wall_1.Tp[4],WaterHeating.Wall_1.Tp[3],WaterHeating.Wall_1.Tp[2],WaterHeating.Wall_1.Tp[1],WaterHeating.pipe_1.h[11],WaterHeating.pipe_1.h[10],WaterHeating.pipe_1.h[9],WaterHeating.pipe_1.h[8],WaterHeating.pipe_1.h[7],WaterHeating.pipe_1.h[6],WaterHeating.pipe_1.h[5],WaterHeating.pipe_1.h[4],WaterHeating.pipe_1.h[3],WaterHeating.pipe_1.h[2],WaterHeating.pipe_1.Q[11],WaterHeating.pipe_1.Q[10],WaterHeating.pipe_1.Q[9],WaterHeating.pipe_1.Q[8],WaterHeating.pipe_1.Q[7],WaterHeating.pipe_1.Q[6],WaterHeating.pipe_1.Q[5],WaterHeating.pipe_1.Q[4],WaterHeating.pipe_1.Q[3],WaterHeating.pipe_1.Q[2],WaterHeating.pipe_1.Q[1],WaterHeating.pipe_1.P[11],WaterHeating.pipe_1.P[10],WaterHeating.pipe_1.P[9],WaterHeating.pipe_1.P[8],WaterHeating.pipe_1.P[7],WaterHeating.pipe_1.P[6],WaterHeating.pipe_1.P[5],WaterHeating.pipe_1.P[4],WaterHeating.pipe_1.P[3],WaterHeating.pipe_1.P[2],WaterHeating.Wall_3.Tp[20],WaterHeating.Wall_3.Tp[19],WaterHeating.Wall_3.Tp[18],WaterHeating.Wall_3.Tp[17],WaterHeating.Wall_3.Tp[16],WaterHeating.Wall_3.Tp[15],WaterHeating.Wall_3.Tp[14],WaterHeating.Wall_3.Tp[13],WaterHeating.Wall_3.Tp[12],WaterHeating.Wall_3.Tp[11],WaterHeating.Wall_3.Tp[10],WaterHeating.Wall_3.Tp[9],WaterHeating.Wall_3.Tp[8],WaterHeating.Wall_3.Tp[7],WaterHeating.Wall_3.Tp[6],WaterHeating.Wall_3.Tp[5],WaterHeating.Wall_3.Tp[4],WaterHeating.Wall_3.Tp[3],WaterHeating.Wall_3.Tp[2],WaterHeating.Wall_3.Tp[1],WaterHeating.pipe_3.h[21],WaterHeating.pipe_3.h[20],WaterHeating.pipe_3.h[19],WaterHeating.pipe_3.h[18],WaterHeating.pipe_3.h[17],WaterHeating.pipe_3.h[16],WaterHeating.pipe_3.h[15],WaterHeating.pipe_3.h[14],WaterHeating.pipe_3.h[13],WaterHeating.pipe_3.h[12],WaterHeating.pipe_3.h[11],WaterHeating.pipe_3.h[10],WaterHeating.pipe_3.h[9],WaterHeating.pipe_3.h[8],WaterHeating.pipe_3.h[7],WaterHeating.pipe_3.h[6],WaterHeating.pipe_3.h[5],WaterHeating.pipe_3.h[4],WaterHeating.pipe_3.h[3],WaterHeating.pipe_3.h[2],WaterHeating.pipe_3.Q[21],WaterHeating.pipe_3.Q[20],WaterHeating.pipe_3.Q[19],WaterHeating.pipe_3.Q[18],WaterHeating.pipe_3.Q[17],WaterHeating.pipe_3.Q[16],WaterHeating.pipe_3.Q[15],WaterHeating.pipe_3.Q[14],WaterHeating.pipe_3.Q[13],WaterHeating.pipe_3.Q[12],WaterHeating.pipe_3.Q[11],WaterHeating.pipe_3.Q[10],WaterHeating.pipe_3.Q[9],WaterHeating.pipe_3.Q[8],WaterHeating.pipe_3.Q[7],WaterHeating.pipe_3.Q[6],WaterHeating.pipe_3.Q[5],WaterHeating.pipe_3.Q[4],WaterHeating.pipe_3.Q[3],WaterHeating.pipe_3.Q[2],WaterHeating.pipe_3.Q[1],WaterHeating.pipe_3.P[21],WaterHeating.pipe_3.P[20],WaterHeating.pipe_3.P[19],WaterHeating.pipe_3.P[18],WaterHeating.pipe_3.P[17],WaterHeating.pipe_3.P[16],WaterHeating.pipe_3.P[15],WaterHeating.pipe_3.P[14],WaterHeating.pipe_3.P[13],WaterHeating.pipe_3.P[12],WaterHeating.pipe_3.P[11],WaterHeating.pipe_3.P[10],WaterHeating.pipe_3.P[9],WaterHeating.pipe_3.P[8],WaterHeating.pipe_3.P[7],WaterHeating.pipe_3.P[6],WaterHeating.pipe_3.P[5],WaterHeating.pipe_3.P[4],WaterHeating.pipe_3.P[3],WaterHeating.pipe_3.P[2],WaterHeating.WaterHeating.Tp,WaterHeating.WaterHeating.Vl,WaterHeating.WaterHeating.hv,WaterHeating.WaterHeating.hl,WaterHeating.WaterHeating.P) * Number of discrete variables: 11 ($whenCondition3,$whenCondition2,$whenCondition1,checkValve.tferme,checkValve.touvert,checkValve.ouvert,regulation_Niveau.echelon.yL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.edge.uL.signal,regulation_Niveau.pIsat1.Integrateur1.x0,singularPressureLossPurge.C1.diff_on_2) * Number of discrete states: 5 (checkValve.touvert,checkValve.tferme,regulation_Niveau.echelon.yL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (1392): * Single equations (assignments): 1256 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 5 * When equations: 2 * If-equations: 0 * Equation systems (not torn): 42 * Torn equation systems: 85 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 42 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 41 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 44 systems {(1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (2,6), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,3), (1,3), (2,7), (3,10), (1,4)} Notification: Performance of Backend phase and start with SimCode phase: time 0.2028/10.05, allocations: 63.08 MB / 2.819 GB, free: 193 MB / 0.8887 GB Notification: Performance of simCode: created initialization part: time 0.09073/10.14, allocations: 30.5 MB / 2.849 GB, free: 162.4 MB / 0.8887 GB Notification: Performance of simCode: created event and clocks part: time 1.5e-05/10.14, allocations: 7.188 kB / 2.849 GB, free: 162.4 MB / 0.8887 GB Notification: Performance of simCode: created simulation system equations: time 0.05097/10.19, allocations: 23.79 MB / 2.872 GB, free: 137.5 MB / 0.8887 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.02454/10.22, allocations: 2.206 MB / 2.875 GB, free: 135.6 MB / 0.8887 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.7488/10.97, allocations: 179.3 MB / 3.05 GB, free: 401.9 MB / 0.8887 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.01063/10.98, allocations: 5.959 MB / 3.056 GB, free: 400.7 MB / 0.8887 GB Notification: Performance of simCode: alias equations: time 0.02099/11, allocations: 4.761 MB / 3.06 GB, free: 400.6 MB / 0.8887 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.01581/11.02, allocations: 5.379 MB / 3.065 GB, free: 396.6 MB / 0.8887 GB Notification: Performance of SimCode: time 1.533e-06/11.02, allocations: 0 / 3.065 GB, free: 396.6 MB / 0.8887 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 1.034/12.05, allocations: 0.5083 GB / 3.574 GB, free: 304.4 MB / 0.8887 GB Notification: Performance of buildModelFMU: Generate platform static: time 62.99/75.04, allocations: 11.86 kB / 3.574 GB, free: 304.4 MB / 0.8887 GB " [Timeout remaining time 584] (rm -f ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.pipe >> ../files/ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.sim & /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_Islanding_fmu --startTime=0 --stopTime=3000 --stepSize=1.2 --timeout=50 --tolerance=1e-06 ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_Islanding.fmu > ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.pipe 2>&1) [Timeout 52.5] [Calling os._exit(0), Time elapsed: 81.28571249602828] Failed to read output from testmodel.py, exit status != 0: 75.63174754893407 75.64241285 72.587246299 Calling exit ...