/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Modelica_trunk_Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.SynchronousMachines.SMPM_FieldWeakening_res.mat --tempDir=temp_Modelica_trunk_Modelica_Magnetic_QuasiStatic_FundamentalWave_Examples_BasicMachines_SynchronousMachines_SMPM_FieldWeakening_fmu --startTime=0 --stopTime=2.5 --stepSize=0.0001 --timeout=50 --tolerance=1e-06 Modelica_trunk_Modelica_Magnetic_QuasiStatic_FundamentalWave_Examples_BasicMachines_SynchronousMachines_SMPM_FieldWeakening.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_trunk_Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.SynchronousMachines.SMPM_FieldWeakening" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_trunk_Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.SynchronousMachines.SMPM_FieldWeakening" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_trunk_Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.SynchronousMachines.SMPM_FieldWeakening/model-e9fwxzuv" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_trunk_Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.SynchronousMachines.SMPM_FieldWeakening" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Modelica_trunk_Modelica_Magnetic_QuasiStatic_FundamentalWave_Examples_BasicMachines_SynchronousMachines_SMPM_FieldWeakening.fmu - startTime: 0.000000 - stopTime: 2.500000 - tolerance: 0.000001 - stepSize: 0.000100 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Modelica_trunk_Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.SynchronousMachines.SMPM_FieldWeakening_res.mat (bufferSize=1) info: Variable model.root.Modelica_trunk_Modelica_Magnetic_QuasiStatic_FundamentalWave_Examples_BasicMachines_SynchronousMachines_SMPM_FieldWeakening.terminalBox.terminalConnection will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | Solving non-linear system 1327 failed at time=0.981799999999908. | | | | For more information please use -lv LOG_NLS. fmi2DoStep: ##CVODE## -8 error occurred at time = 0.981699999999908.error: [fmi2logger] [fmi2Fatal] Modelica_trunk_Modelica_Magnetic_QuasiStatic_FundamentalWave_Examples_BasicMachines_SynchronousMachines_SMPM_FieldWeakening/logStatusFatal: fmi2DoStep: CVODE integrator step failed. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Modelica_trunk_Modelica_Magnetic_QuasiStatic_FundamentalWave_Examples_BasicMachines_SynchronousMachines_SMPM_FieldWeakening" error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 3 errors