/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.ThermalZones.ReducedOrder.Examples.SimpleRoomTwoElementsNonConstantTGround_res.mat --tempDir=temp_Buildings_latest_Buildings_ThermalZones_ReducedOrder_Examples_SimpleRoomTwoElementsNonConstantTGround_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=3600 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_ReducedOrder_Examples_SimpleRoomTwoElementsNonConstantTGround.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ReducedOrder.Examples.SimpleRoomTwoElementsNonConstantTGround" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ReducedOrder.Examples.SimpleRoomTwoElementsNonConstantTGround" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ReducedOrder.Examples.SimpleRoomTwoElementsNonConstantTGround/model-ri53h301" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ReducedOrder.Examples.SimpleRoomTwoElementsNonConstantTGround" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_ThermalZones_ReducedOrder_Examples_SimpleRoomTwoElementsNonConstantTGround.fmu - startTime: 0.000000 - stopTime: 31536000.000000 - tolerance: 0.000001 - stepSize: 3600.000000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Media/package.mo:6225:7-6229:3:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((thermalZoneTwoElements.volAir.dynBal.medium.T >= 273.15 and thermalZoneTwoElements.volAir.dynBal.medium.T <= 373.15)) --> " | | | | Temperature T (= 0 K) is not | | | | in the allowed range (273.15 K <= T <= 373.15 K) | | | | required from medium model "SimpleAir". | | | | " error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_ThermalZones_ReducedOrder_Examples_SimpleRoomTwoElementsNonConstantTGround/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_exitInitializationMode failed for FMU "model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Examples_SimpleRoomTwoElementsNonConstantTGround" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors