/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuning_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuning" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuning" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuning/model-snu1bxrm" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuning" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOnRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOnRec.yRec.y, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOffRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOffRec.yRec.y, has value: 0" info: Result file: Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIControlAutoTuning_res.mat (bufferSize=1) LOG_ASSERT | debug | division leads to inf or nan at time 162.72, (a=inf) / (b=0.377379), where divisor b is: con.conProMod.timConDel.sub1.y error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | debug | division leads to inf or nan at time 162.72, (a=inf) / (b=0.377379), where divisor b is: con.conProMod.timConDel.sub1.y error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning" LOG_ASSERT | debug | division leads to inf or nan at time 162.72, (a=inf) / (b=0.377379), where divisor b is: con.conProMod.timConDel.sub1.y error: [fmi2logger] [fmi2Error] Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIControlAutoTuning/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable con.triTun error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 5 errors