/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn_res.mat --tempDir=temp_Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=400 --tolerance=1e-06 Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn/model-mbzqmy6n" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn/169.fmutmp/sources/Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn_functions.c:10743: Invalid root: (0)^(-1.5) LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn/169.fmutmp/sources/Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn_functions.c:10743: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn/169.fmutmp/sources/Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn_functions.c:10743: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn/169.fmutmp/sources/Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn_functions.c:10743: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | Solving non-linear system 1799 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | error | Failed to solve the initialization problem with global homotopy with equidistant step size. LOG_ASSERT | debug | Unable to solve initialization problem. error: [fmi2logger] [fmi2Error] Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_exitInitializationMode failed for FMU "model.root.Buildings_12_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_InjectionTwoWayVariableReturn" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors