/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Controls.Safety.Examples.OperationalEnvelope_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope_fmu --startTime=0 --stopTime=100 --stepSize=1 --timeout=400 --tolerance=1e-08 Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Controls.Safety.Examples.OperationalEnvelope" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Controls.Safety.Examples.OperationalEnvelope" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Controls.Safety.Examples.OperationalEnvelope/model-z4xsvsfe" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Controls.Safety.Examples.OperationalEnvelope" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope.fmu - startTime: 0.000000 - stopTime: 100.000000 - tolerance: 0.000000 - stepSize: 1.000000 info: Result file: Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Controls.Safety.Examples.OperationalEnvelope_res.mat (bufferSize=1) info: Parameter model.root.Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope.opeEnv.bouMapCoo.tabBou.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope.opeEnv.bouMapCoo.tabBou.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope.opeEnv.bouMapCoo.tabBou.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope.opeEnv.bouMapHea.tabBou.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope.opeEnv.bouMapHea.tabBou.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope.opeEnv.bouMapHea.tabBou.tableName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope/logStatusError: fmi2GetContinuousStates: Invalid argument states[] = NULL. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope" error: [SimulateSingleFMU] oms_simulate failed error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope/logStatusError: fmi2Terminate: Illegal co-simulation call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Controls_Safety_Examples_OperationalEnvelope" failed error: [terminate] Termination of system "model.root" failed info: 2 warnings info: 6 errors