/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu --startTime=1.5552e+07 --stopTime=1.56384e+07 --stepSize=34.56 --timeout=400 --tolerance=1e-07 Buildings_11_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC/model-1amsqol0" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: Buildings_11_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC.fmu - startTime: 15552000.000000 - stopTime: 15638400.000000 - tolerance: 0.000000 - stepSize: 34.560000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-07 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: Buildings_11_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_res.mat (bufferSize=1) error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Utilities/Streams.mo:113: The boundary mass fractions in medium "Air" in model "Boundary_pT" do not sum up to 1. Instead, sum(X_boundary) = 1: X_boundary[1] = 0.0100969 "water" X_boundary[2] = 0.989903 "air" error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.Buildings_11_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC" error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 4 errors