Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=14160 tolerance=1e-09 numberOfIntervals=2500 stepSize=5.664 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Storage.Heat.HotWaterStorage_constProp_L4.Check.CheckStratifiedHotWaterStorage_L4_Loading_inclElHeater -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0782287s reading init.xml | | | | | | 0.00639622s reading info.xml | | | | | | 0.000477638s [ 1.0%] pre-initialization | | | | | | 0.0222272s [ 47.9%] initialization | | | | | | 7.3338e-05s [ 0.2%] steps | | | | | | 0.0100326s [ 21.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00033934s [ 0.7%] event-handling | | | | | | 0.00131569s [ 2.8%] overhead | | | | | | 0.0118973s [ 25.7%] simulation | | | | | | 0.0463631s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 5 time events | | | | | solver: ida | | | | | | 2071 steps taken | | | | | | 3050 calls of functionODE | | | | | | 232 evaluations of jacobian | | | | | | 120 error test failures | | | | | | 2 convergence test failures | | | | | | 0.00120383s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.