Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=2500 stepSize=4 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Storage.Heat.HotWaterStorage_constProp_L2.Check.Check_HotWaterStorage_constProp_L2 -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0269209s reading init.xml | | | | | | 0.00170858s reading info.xml | | | | | | 0.000153559s [ 0.3%] pre-initialization | | | | | | 0.0267707s [ 57.6%] initialization | | | | | | 6.141e-06s [ 0.0%] steps | | | | | | 0.000810302s [ 1.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 5.3663e-05s [ 0.1%] event-handling | | | | | | 0.00167889s [ 3.6%] overhead | | | | | | 0.0170379s [ 36.6%] simulation | | | | | | 0.0465112s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 1 time events | | | | | solver: ida | | | | | | 267 steps taken | | | | | | 371 calls of functionODE | | | | | | 76 evaluations of jacobian | | | | | | 7 error test failures | | | | | | 5 convergence test failures | | | | | | 0.000555782s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.