Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=4e+06 tolerance=1e-06 numberOfIntervals=4444 stepSize=900.09 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Storage.Electrical.Check.TestLeadAcidBattery -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0298551s reading init.xml | | | | | | 0.00197526s reading info.xml | | | | | | 0.000185338s [ 0.3%] pre-initialization | | | | | | 0.0325689s [ 56.6%] initialization | | | | | | 1.213e-06s [ 0.0%] steps | | | | | | 0.00828277s [ 14.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000114821s [ 0.2%] event-handling | | | | | | 0.00164163s [ 2.9%] overhead | | | | | | 0.0147354s [ 25.6%] simulation | | | | | | 0.0575301s [100.0%] total | | | | | events | | | | | | 16 state events | | | | | | 1 time events | | | | | solver: ida | | | | | | 8906 steps taken | | | | | | 16850 calls of functionODE | | | | | | 6262 evaluations of jacobian | | | | | | 2245 error test failures | | | | | | 82 convergence test failures | | | | | | 0.00400594s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.