Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=432000 tolerance=1e-06 numberOfIntervals=480 stepSize=900 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.Test_idContrMFlow_temp -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0182608s reading init.xml | | | | | | 0.00153107s reading info.xml | | | | | | 7.446e-05s [ 0.3%] pre-initialization | | | | | | 0.0233597s [ 87.1%] initialization | | | | | | 5.18e-06s [ 0.0%] steps | | | | | | 4.963e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000519737s [ 1.9%] event-handling | | | | | | 0.000293388s [ 1.1%] overhead | | | | | | 0.00256975s [ 9.6%] simulation | | | | | | 0.0268272s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 1 time events | | | | | solver: euler | | | | | | 490 steps taken | | | | | | 490 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.