Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=167 stepSize=59.8802 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Producer.Heat.Heat2Heat.Check.TestSubstation_indirect_noStorage_L1 -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0152662s reading init.xml | | | | | | 0.00108244s reading info.xml | | | | | | 0.000152336s [ 0.6%] pre-initialization | | | | | | 0.0236167s [ 96.0%] initialization | | | | | | 1.983e-06s [ 0.0%] steps | | | | | | 0.000186834s [ 0.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.7831e-05s [ 0.1%] event-handling | | | | | | 0.000153553s [ 0.6%] overhead | | | | | | 0.00048004s [ 2.0%] simulation | | | | | | 0.0246093s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 3 time events | | | | | solver: ida | | | | | | 66 steps taken | | | | | | 66 calls of functionODE | | | | | | 58 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 4.2432e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.