Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=96 stepSize=900 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Producer.Electrical.Photovoltaics.QuasiStationary.Check.TestLowVoltageGridWithPVModules -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ambient/GHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/GHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Wind_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Wind_Hamburg_3600s_TMY.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0225559s reading init.xml | | | | | | 0.00193873s reading info.xml | | | | | | 0.000237697s [ 0.1%] pre-initialization | | | | | | 0.0313537s [ 14.2%] initialization | | | | | | 0.002144s [ 1.0%] steps | | | | | | 0.0120905s [ 5.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 8.3841e-05s [ 0.0%] event-handling | | | | | | 0.000124273s [ 0.1%] overhead | | | | | | 0.174341s [ 79.1%] simulation | | | | | | 0.220375s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 2 time events | | | | | solver: ida | | | | | | 7779 steps taken | | | | | | 17116 calls of functionODE | | | | | | 11604 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 3849 convergence test failures | | | | | | 0.08173s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.