Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=12000 tolerance=1e-06 numberOfIntervals=200 stepSize=60 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Producer.Electrical.Others.Check.TestBiomass -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0161803s reading init.xml | | | | | | 0.00134635s reading info.xml | | | | | | 0.000176773s [ 0.7%] pre-initialization | | | | | | 0.0231172s [ 93.8%] initialization | | | | | | 1.263e-06s [ 0.0%] steps | | | | | | 0.000518551s [ 2.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 5.9452e-05s [ 0.2%] event-handling | | | | | | 0.000149419s [ 0.6%] overhead | | | | | | 0.000621993s [ 2.5%] simulation | | | | | | 0.0246447s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 15 time events | | | | | solver: ida | | | | | | 580 steps taken | | | | | | 684 calls of functionODE | | | | | | 301 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 0 convergence test failures | | | | | | 9.3576e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.