Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=30 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.012 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Grid.Electrical.SecondaryControl.Check.TestSecondaryBalancingController -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0420784s reading init.xml | | | | | | 0.00105343s reading info.xml | | | | | | 0.000167906s [ 0.4%] pre-initialization | | | | | | 0.0422446s [ 91.8%] initialization | | | | | | 8.01e-07s [ 0.0%] steps | | | | | | 0.000449634s [ 1.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.774e-05s [ 0.1%] event-handling | | | | | | 0.00089813s [ 2.0%] overhead | | | | | | 0.00221383s [ 4.8%] simulation | | | | | | 0.0460026s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 2 time events | | | | | solver: ida | | | | | | 104 steps taken | | | | | | 112 calls of functionODE | | | | | | 90 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 3.405e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.