Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Grid.Electrical.LumpedPowerGrid.Check.LocalPlantInteractingWithUCTE_withIncident -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0224854s reading init.xml | | | | | | 0.00199334s reading info.xml | | | | | | 0.000242326s [ 0.8%] pre-initialization | | | | | | 0.0236335s [ 78.9%] initialization | | | | | | 1.452e-06s [ 0.0%] steps | | | | | | 0.0009481s [ 3.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.4909e-05s [ 0.1%] event-handling | | | | | | 0.00103351s [ 3.5%] overhead | | | | | | 0.00405585s [ 13.5%] simulation | | | | | | 0.0299397s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 1 time events | | | | | solver: ida | | | | | | 207 steps taken | | | | | | 280 calls of functionODE | | | | | | 108 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 8 convergence test failures | | | | | | 0.000471795s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.