Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Consumer.Heat.Check.TestThermalHeatConsumer -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Consumer/Heat/ThermalHeatConsumer.mo:149:3-149:123:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((consumer.deltaT_water >= 0.0), consumer.deltaT_water=-10.15711147550837) --> "Variable violating min constraint: 0.0 <= consumer.deltaT_water, has value: -10.1571" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0201187s reading init.xml | | | | | | 0.00174218s reading info.xml | | | | | | 0.00017557s [ 0.2%] pre-initialization | | | | | | 0.0250292s [ 32.9%] initialization | | | | | | 1.7563e-05s [ 0.0%] steps | | | | | | 0.000737565s [ 1.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 5.089e-05s [ 0.1%] event-handling | | | | | | 0.00201219s [ 2.6%] overhead | | | | | | 0.0480452s [ 63.2%] simulation | | | | | | 0.0760682s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 64 steps taken | | | | | | 78 calls of functionODE | | | | | | 17 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000384701s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.