Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Consumer.Electrical.Check.CheckSLPElectricConsumer -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/StandardLoadProfiles/G0_Hamburg_Normalized_1kWh_900s_2012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/StandardLoadProfiles/G0_Hamburg_Normalized_1kWh_900s_2012.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00856587s reading init.xml | | | | | | 0.000719032s reading info.xml | | | | | | 4.8021e-05s [ 0.2%] pre-initialization | | | | | | 0.0261022s [ 90.5%] initialization | | | | | | 1.823e-06s [ 0.0%] steps | | | | | | 2.4727e-05s [ 0.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.66e-05s [ 0.1%] event-handling | | | | | | 0.000795294s [ 2.8%] overhead | | | | | | 0.00183338s [ 6.4%] simulation | | | | | | 0.0288321s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 3 time events | | | | | solver: euler | | | | | | 2502 steps taken | | | | | | 2502 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.