Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=1200 tolerance=1e-05 numberOfIntervals=2500 stepSize=0.48 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Components.Heat.Fan.Check.TestFan -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Components/Heat/Fan/Fan_L1.mo:186:2-186:62:writable] | | | | The following assertion has been violated at time 61.440000 | | | | ((fan.E_check >= 0.0), fan.E_check=-1.275596635066942e-10) --> "Variable violating min constraint: 0.0 <= fan.E_check, has value: -1.2756e-10" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.030928s reading init.xml | | | | | | 0.00157614s reading info.xml | | | | | | 0.000199756s [ 0.5%] pre-initialization | | | | | | 0.0265924s [ 69.1%] initialization | | | | | | 3.767e-06s [ 0.0%] steps | | | | | | 0.000623092s [ 1.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 4.8499e-05s [ 0.1%] event-handling | | | | | | 0.00132398s [ 3.4%] overhead | | | | | | 0.00967683s [ 25.2%] simulation | | | | | | 0.0384683s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 2 time events | | | | | solver: ida | | | | | | 165 steps taken | | | | | | 199 calls of functionODE | | | | | | 51 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 2.4689e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.