Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Components.Heat.Check.TestHeatExchanger -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0160907s reading init.xml | | | | | | 0.00129539s reading info.xml | | | | | | 0.000183215s [ 0.4%] pre-initialization | | | | | | 0.0241296s [ 50.8%] initialization | | | | | | 7.655e-06s [ 0.0%] steps | | | | | | 0.000819834s [ 1.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 9.3796e-05s [ 0.2%] event-handling | | | | | | 0.00160768s [ 3.4%] overhead | | | | | | 0.0206908s [ 43.5%] simulation | | | | | | 0.0475325s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 3 time events | | | | | solver: ida | | | | | | 237 steps taken | | | | | | 301 calls of functionODE | | | | | | 66 evaluations of jacobian | | | | | | 8 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000284317s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.