Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.008 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../TransiEnt_TransiEnt.Components.Electrical.Machines.Check.CheckActivePowerGenerator -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0139761s reading init.xml | | | | | | 0.000710415s reading info.xml | | | | | | 0.000163908s [ 0.6%] pre-initialization | | | | | | 0.023706s [ 86.9%] initialization | | | | | | 7.91e-07s [ 0.0%] steps | | | | | | 0.000434038s [ 1.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.2684e-05s [ 0.0%] event-handling | | | | | | 0.000801896s [ 2.9%] overhead | | | | | | 0.00216572s [ 7.9%] simulation | | | | | | 0.027285s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 54 steps taken | | | | | | 77 calls of functionODE | | | | | | 30 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 2.2002e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.